BEKA 2019 All rights reserved!
-42-
BA
L_
ZE
PT
O_1
01
9D
E_
EN.docx
11.4 Operational mode of lubrication duration P1 to P3
The lubrication duration can only be determined
time-dependent
for the device 10142862.
It can be determined
time-dependent
or
pulse-dependent
for the device 10144013.
The lubrication duration is displayed in the
left segment
of the display and can be set via the
left control key
.
11.4.1 Operational mode of time-dependent lubrication duration P1
The device operates dependent on the set lubrication duration in program
P1
.
Setting:
Hold down the
left
control key until the
current setting appears in the left
segment of the display, e.g. “
1
”
Press the
left
control key as often as
required until the desired setting is
reached.
The control saves the setting automatically;
no further confirmation is necessary.
Display
0
1
2
3
4
5
6
7
8
9
Lubrication duration (min)
0,5
1
2
3
4
5
6
7
8
9
11.4.2 Operational mode of time-dependent lubrication duration with system pressure monitoring P2
In program
P2
, the device operates as described in chapter
11.4.1
“Operational mode of time
-
dependent lubrication duration P1”
.
In addition, the operating pressure in the lubrication system is monitored by a micro switch which is attached at the pressure limiting
valve.
If the pressure in the lubrication system exceeds the set value (290 bar), the pressure limiting valve opens and the micro switch is
actuated. The micro switch sends a signal to the control. The device shows the error
E5
and signals a malfunction (see chapter
15.1
“Signal displays of the control”
).
After eliminating the cause of error, the error must be reset as described in chapter
15.2 “Resetting the error
E5
”
.
The micro switch is connected to the bushing M12x1.
If program
P2
is selected, a micro switch
must
be connected, otherwise the device displays the error
E5
and
signals a malfunction (see chapter
15.1
“Signal displays of the control“
).
Time-dependent
lubrication duration
Time-dependent
cycle duration
Notice!
Summary of Contents for ZEPTO
Page 27: ...27 BEKA 2019 Alle Rechte vorbehalten BAL_ZEPTO_1019DE_EN docx 18 Ma zeichnung...
Page 52: ...BEKA 2019 All rights reserved 52 BAL_ZEPTO_1019DE_EN docx 18 Dimensional drawing...
Page 53: ...53 BEKA 2019 BAL_ZEPTO_1019DE_EN docx Einbauerkl rung Declaration of incorporation...
Page 54: ...BEKA 2019 54 BAL_ZEPTO_1019DE_EN docx...