Select the required sub-function

oP2

 

:

 

on1

Time oP2 turns 

on

 first time

oP2

 

:

 

oFF1

Time oP2 turns 

off

 first time

oP2

 

:

 

on2

Time oP2 turns 

on

 second time

oP2

 

:

 

oFF2

Time oP2 turns 

off

 second time

When selected pressing

(

will show the existing

time with the hours flashing.

Using the

*

or

&

button adjust the hours and then press

(

to

transfer control to the minutes display, pressing

(

again will transfer control to the seconds display.
When the time has been set as required press

)

to

return to the sub-menu from which another

on

/

off

time may be selected for adjustment. When all the

on

/

off

times have been entered, return to the

configuration menu by pressing the 

)

 button twice.

8.4.13 Access control output 

on

 & 

off

  

times

             from display mode:  

AC5P

This function activates a separate menu that
provides direct access to the control output's

on

and

off

times when the Clock is the display mode

(displaying time). An operator may therefore adjust
the

on

and

off

times without having access to the

instrument configuration menu. Further protection is
provided by a separate security code. When this
function is enabled the

on

and

off

times of the two

control outputs may be adjusted from the display
mode by simultaneously operating the

(

and

*

push buttons.

The function contains two sub-

functions,

EnbL

which activates the function and

ACCd

which defines a separate access code that

may be used to prevent the

on

and

off

times being

accidentally adjusted from the display mode.

To check or change the function, select

AC5P

in the

configuration menu and press

(

which will reveal

the

EnbL

prompt, pressing

(

again will show if the

function is

on

or

oFF

. If adjustment of the control

output times from the display mode is not required
press the

*

or

&

button to select

off

and then

press

)

twice to return to the configuration menu.

If the function is required, select

on

and press

)

to

return to the

EnbL

prompt from which

ACCd

, which

allows a separate access code to be entered, can
be selected by pressing the 

*

 or 

&

 button.

Access to the control output times from the display
mode may be protected by a four digit alphanumeric
security code which must be entered to gain access.
Default security code

0000

allows unrestricted

access. With

ACCd

displayed, press

(

to enter a

new access code. The BA577E Clock will display

0000

with one digit flashing. The flashing digit may

be adjusted using the

*

or

&

push button, when

set as required operating the

(

button will transfer

control to the next digit.

When all the digits have

been adjusted press

)

twice to return to the

AC5P

prompt in the configuration menu. The revised
security code will be activated when the BA577E is
returned to the display mode.

8.4.14 Security code:   

CodE

Access to the instrument's configuration menu may
be protected by a four digit alphanumeric security
code which must be entered to gain access.

New

instruments are configured with the default security
code

0000

which allows unrestricted access to all

configuration functions.

To enter a new security code select

CodE

from the

configuration menu and press

(

which will cause

the Clock to display

0000

with one digit flashing.

The flashing digit may be adjusted using the

*

and

&

push button, when set as required operating the

(

button will transfer control to the next digit.

When all the digits have been adjusted press

)

to

return to the

CodE

prompt. The revised security code

will be activated when the Clock is returned to the
display mode.  

Please contact BEKA associates sales department if
the security code is lost.

8.4.15 Reset configuration to Clock factory

defaults:.   

r5Et dEF

When the BA577E is configured as a Clock, this
function resets the configuration to the Clock factory
defaults shown in sections 8.4 of this  manual.

To

reset

the

instrument

configuration

select

r5Et dEF

from the configuration menu and press

(

.

The Clock will display

0000

with the first digit

flashing which is a request to confirm the instruction
by entering

5urE

. Using the

*

or

&

button set the

first flashing digit to

5

and press

(

to transfer

control to the second digit which should be set to

u

.

When

5urE

has been entered pressing the

)

button will reset all the configuration functions to the
factory defaults and return the instrument to the
display mode as a Clock with default configuration.

Summary of Contents for BA577E

Page 1: ...Issue 4 3rd July 2018 BA577E One input General purpose Timer or Clock Issue 4...

Page 2: ...epeat timing cycle CYCLE5 5 5 12 Cycle function enable EnbL 5 5 13 Cycle count cycl cnt 5 5 14 Restart delay r5t dela 5 5 15 Adjusting the set time 5Et t and restart delay r5t dela from the display mo...

Page 3: ...8 4 8 Enable Control output 1 EnbL 8 4 9 On and off times oP 1 on 1 oP 1 off 1 oP 1 on 2 oP 1 off 2 8 4 10 Control output 2 Optional oP2 8 4 11 Enable control output 2 EnbL 8 4 12 On and off times oP2...

Page 4: ...s the basic circuit that is used for all BA577E Timer installations Clock installations are the same except that the input terminals 5 6 are not used For simplicity the optional control outputs are de...

Page 5: ...e circuit to prevent false triggering of the instrument Three levels of debounce protection are available See section 5 5 6 2 2 5 Voltage pulse input Two voltage pulse input ranges are independently s...

Page 6: ...ecommended panel cut out dimensions To achieve an IP66 seal between the instrument enclosure and the instrument panel the smaller tolerance aperture must be used Although the front of the BA577E has I...

Page 7: ...g clamps 3 4 Scale card The BA577E s units of measurement are shown on a printed scale card in a window at the right hand side of the display The scale card is mounted on a flexible strip that is inse...

Page 8: ...lay through which a scale card showing the units of time such as hours can be seen New instruments are fitted with a scale card showing the units of measurement specified when the instrument was order...

Page 9: ...plished via the front panel push buttons or by a remote contact A grand total time is maintained which can be viewed by operating the front panel push buttons It may be reset to zero from within the c...

Page 10: ...5 Shows in succession firmware version number instrument function elap5e and any output accessories that are fitted A Dual Control Outputs Access to configuration menu 5 3 Displays when configured as...

Page 11: ...t the end of the delay time automatically returns to Running Complete Entered automatically from Running when there are no more timing cycles to perform When the CYCLE5 function is enabled the timing...

Page 12: ...he instrument using the or push button to adjust the flashing digit and the push button to transfer control to the next digit If the correct code has been entered pressing will cause the first paramet...

Page 13: ...ContACt Switch contact Energise input by linking terminals 3 4 See section 5 5 5 dEbounCE Defines the level of debounce applied to the input to prevent false functioning dEFAuLt HEAVY LiGHt See sectio...

Page 14: ...display mode to 5Et t and r5t dela See section 5 5 15 Display Summary of function uP or dn Direction of count Defines whether the Timer times down from 5Et t to zero or times up from zero to the set...

Page 15: ...as control output 1 See section 5 5 26 Display Summary of function CLr Gtot Reset grand total to zero This function resets the grand total which represents the total Timer run time from within the con...

Page 16: ...s twice to return to the configuration menu or repeatedly press the or button until the required type of input is displayed and then press twice to return to the configuration menu One of following si...

Page 17: ...at start of each period 02 11 Current Number of cycles cycle requested not shown number when cycle is continuously repeated LabEL Exactly the same as 5td but timer status i e CYCLE or dELAY is shown p...

Page 18: ...18...

Page 19: ...19...

Page 20: ...o the next digit When set as required enter the selection and return to the cycl cnt prompt in the sub menu by operating the button 5 5 14 Restart delay r5t dela This sub function defines the time del...

Page 21: ...diately Continue When power is restored the Timer will continue from where it stopped without any manual intervention To check or change the function select P fail from the configuration menu and pres...

Page 22: ...ation example in section 6 2 of this manual illustrate the use of the control outputs Further examples can be found in Application Guide AG374 which is available on the BEKA website 5 5 22 Control out...

Page 23: ...select op1 dELA from the control output 1 sub menu and press which will reveal the existing delay time with one digit flashing The flashing digit can be adjusted using the or button and the button to...

Page 24: ...trol to the second digit which should be set to u When 5urE has been entered pressing the button will reset all the configuration functions and return the instrument to the display mode Note r5Et dEF...

Page 25: ...topped when the start button is operated Fig 11 Control of a solenioid valve The required instrument configuration for this example are shown below Function Display Setting Access code CodE 0000 Funct...

Page 26: ...configuration menu Incorrect security code That the correct security code is being used Contact BEKA if code is lost 7 2 Fault finding after commissioning ENSURE PLANT SAFETY BEFORE STARTING MAINTENAN...

Page 27: ...regularly checked Inspection frequency should be chosen to suit the environmental conditions 7 5 Guarantee Instruments which fail within the guarantee period should be returned to BEKA associates or o...

Page 28: ...ment s permanent memory Following initialisation the instrument will display a flashing display which is a request for the local time to be entered The clock will not start to function until a display...

Page 29: ...out this manual push buttons are shown as and and legends displayed by the Clock are shown in a seven segment font as they appear on the instrument e g di5PLAY and CodE Access to the configuration men...

Page 30: ...30...

Page 31: ...ntrol output 1 Optional Control output 1 can turn on output closed and off output open twice in each twenty four hour period This function contains five sub function EnbL Enables output 1 and defines...

Page 32: ...time is entered the Clock will display a flashing 00 00 00 or 00 00 for 24 hour formats or A12 00 00 or A12 00 for 12 hour formats To adjust the clock set time select 5Et from the configuration menu a...

Page 33: ...tered return to the configuration menu by pressing the button twice 8 4 10 Control output 2 Optional oP2 Control output 2 is an optional factory fitted output which can be configured to turn on output...

Page 34: ...m the display mode may be protected by a four digit alphanumeric security code which must be entered to gain access Default security code 0000 allows unrestricted access With ACCd displayed press to e...

Page 35: ...ill then change the instrument to a Clock and return the display to FunCtion in the configuration menu Step 3 Select display format Using the or button select di5PLAY in the configuration menu and pre...

Page 36: ...sed access to the configuration menu Using the or button select CodE from the configuration menu and press which will reveal 0000 with the first digit flashing This example requires the security code...

Page 37: ...ANCE If a BA577E fails after it has been functioning correctly as a Clock the following table may help to identify the cause of the failure Symptom Cause Check No display No power supply That there is...

Page 38: ...8 10 6 Customer comments BEKA is always pleased to receive comments from customers about our products and services All communications are acknowledged and whenever possible suggestions are implemented...

Reviews: