1. Description
2. Operation
2.1 Initialisation
2.2 Controls
2.3 Displays
3. System Design
3.1 Power supply
3.2 Pulse input
3.2.1 Switch contact input
3.2.2 2-wire proximity detector input
3.2.3 Open collector input
3.2.4 Magnetic pick-off input
3.2.5 Voltage pulse input
3.3 Remote reset
4. Installation
4.1 Location
4.2 Installation procedure
4.3 EMC
4.4 Counter earthing
4.5 Scale card
5. Configuration and Calibration
5.1 Configuration structure
5.2 Accessing the configuration functions
5.3 Summary of configuration functions
5.4 Input:
inPut
5.5 Input type:
inP. tYPE
5.6 Input debounce:
dEbouncE
5.7 Input pulse counting edge:
Cnt EdgE
5.8 Display update interval:
uPdAtE
5.9 Upper display:
di5P-1
5.10 Lower display:
di5P-2
5.11 Position of the decimal points:
dP
5.12 Total scale factor:
5CALE
.
t
5.13 Rate scale factor:
5CALE
.
r
5.14 Timebase:
t-bA5E
5.15 Display filter:
FiLtEr
5.16 Direction of count:
uP or dn
5.17 Reset value:
CLr VAL
5.18 Local reset:
LoC CLr
5.19 Local total reset:
Clr tot
5.20 Local grand total reset:
Clr Gtot
5.21 Reset grand total from configuration
menu:
Clr Gtot
5.22 Security code:
CodE
5.23 Reset configuration to factory defaults:
r5Et dEF
5.24 Display overflow
6. Configuration example
7. Maintenance
7.1 Fault finding during commissioning
7.2 Fault finding after commissioning
7.3 Servicing
7.4 Routine maintenance
7.5 Guarantee
7.6 Customer comments
8. Accessories
8.1 Scale card
8.2 Tag information
8.3 Alarms
8.3.1 Solid state output
8.3.2 Configuration summary
8.3.3 Alarm enable:
EnbL
8.3.4 Type of alarm:
tYPE
8.3.5 Setpoint adjustment:
5P1
x &
5P2
x
8.3.6 Alarm function:
Hi.
Lo
8.3.7 Alarm output status:
no . nC
8.3.8 Hysteresis:
H5tr
8.3.9
Alarm delay:
dELA
8.3.10 Alarm silence time:
5IL
8.3.11 Flash display when alarm occurs:
FL5H
8.3.12 Access Setpoint:
AC5P
8.3.13 Adjusting alarm setpoints from
display mode.
8.4 Pulse Output
8.4.1 System design
8.4.2 Configuration
8.4.3
Access Pulse output sub-menu:
PuL5E oP
8.4.4 Enable pulse output:
EnbL
8.4.5
Source of pulse output:
5ourCE
8.4.6 Divide output pulse frequency:
diVidE
8.4.7
Output pulse width:
durAtion
8.5 4/20mA output
8.5.1
System design
8.5.2
Configuration
8.5.3
Access 4/20mA output
sub-menu:
4-20 oP
8.5.4
Enable 4/20mA output:
EnbL
8.5.5
Select rate or total source:
4-20tYPE
8.5.6
Display corresponding to
4mA output:
4
.
000
8.5.7
Display corresponding to
20mA output:
20
.
000
8.6 Display backlight
222222222222222222222222222
CONTENTS
The BA567E-SS is CE marked to show compliance with the European EMC Directive 2014/30/EU
Summary of Contents for BA567E-SS
Page 1: ...Issue 6 9th July 2019 BA567E SS Rugged one input General purpose Counter Issue 6 ...
Page 12: ...12 ...
Page 13: ...13 ...