background image

NCR 7448 Workstation

Release 1.3

Site Preparation

B005-0000-1201

Issue D

Summary of Contents for 7448 Workstation

Page 1: ...NCR 7448 Workstation Release 1 3 Site Preparation B005 0000 1201 Issue D...

Page 2: ...described herein may not be marketed by NCR in all parts of the world In some instances photographs are of equipment prototypes Therefore before using this document consult with your NCR representati...

Page 3: ...l applicable national state or local codes regulations and laws Safety Warnings The NCR 7448 Workstation must be connected to an AC outlet that is near the workstation and is easily accessible by the...

Page 4: ...tlet is located installed near the equipment and is easily accessible Attention Le cordon d alimentation est utilis comme interrupteur g n ral La prise de courant doit tre situ e ou install e proximit...

Page 5: ...CSA TUV VDE or those which are recommended by NCR Corporation Environmental Consciousness NCR s concern for the environment is demonstrated by the intelligent power management system of the NCR 7448 W...

Page 6: ...ben b Apr s usage rapporter au point de vente c Ritornare la pila usate al negozio d Contain Nickel Cadmium battery Must be recycled or disposed of properly About this Book This book provides site pre...

Page 7: ...ATION DIAGRAM SYSTEM CONFIGURATION DIAGRAM 10 10 10 10 PHYSICAL CONSIDERATIONS PHYSICAL CONSIDERATIONS PHYSICAL CONSIDERATIONS PHYSICAL CONSIDERATIONS 11 11 11 11 HANDLING SYSTEM COMPONENTS 11 OPERATI...

Page 8: ...tomer Display with Telescope Mount 21 Configuration with 22 TFT Color LCD Display 176 Key Micromotion keyboard and International VFD Customer Display with Telescope Mount 22 COMPONENT DIMENSIONS 23 Ba...

Page 9: ...L REQUIREMENTS ENVIRONMENTAL REQUIREMENTS 44 44 44 44 BAROMETRIC PRESSURE 44 TEMPERATURE 44 HUMIDITY 44 APPENDIX A TRANSIENT PROTECTION APPENDIX A TRANSIENT PROTECTION APPENDIX A TRANSIENT PROTECTION...

Page 10: ...viii Site Preparation Revision Record Issue Date Remarks A August 2000 First Issue B December 2000 Update for Release 1 1 C March 2001 Update for Release 1 2 D December 2001 Update for Release 1 3...

Page 11: ...television interference caused by unauthorized modification of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by NCR The correction of...

Page 12: ......

Page 13: ...y be difficult to detect and correct after installation The NCR 7448 Workstation system consists of separate pieces that may be combined in a variety of configurations Typical configurations are shown...

Page 14: ...l configurations Dimensions and operating clearances are listed in the 7448 Dimensions section to identify the space required by each configuration Use the component drawings in this book and associat...

Page 15: ...Site Preparation 3 7448 Workstation with 80 Key Conventional Keyboard...

Page 16: ...4 Site Preparation Interpreting the Model Number NCR Model 7448 XX XX XX XX Class Number Major Model Code Sub Model Code Power Code Language Code...

Page 17: ...uide B005 0000 1112 7161 Receipt Printer Owner s Guide B005 0000 1067 7161 Receipt Printer Setup Guide B005 0000 1029 7194 Thermal Receipt Printer owner s Guide B005 0000 1097 7196 Thermal Receipt Pri...

Page 18: ...select Information Products Order Form Web Site http inforetail AtlantaGA NCR COM NCR only http www info NCR COM Anyone Online Order Connect System NCR only Phone Order 800 543 2010 US area 622 3727...

Page 19: ...ation 7 SMTP Order Management UnitedK International Mail Order NCR Corporation IPP Dayton 1700 S Paterson Boulevard Dayton OH 45479 USA NCR Corporation 915 High Road North Finchley London N12 ONH Unit...

Page 20: ...nd laws including but not limited to electrical building safety and health are met Provide and install auxiliary power or other equipment as required Provide storage or service areas as required Meet...

Page 21: ...gurations however the safety requirements must be met A dedicated unswitched power line is recommended Refer to the Workstation and Peripherals AC Power Wiring Guide BST0 2115 53 for store AC wiring r...

Page 22: ...rs 1 line 10 digit Numeric 4x20 char Alphanumeric 256x64 pixel International 2x20 char Alphanumeric RS232 Customer Displays 80 key Keyboard 176 key Keyboard MSR Mono LCD Passive Color LCD 2x20 Operato...

Page 23: ...requirements Power requirements Handling System Components Workstation system components can be moved by one person However consider the following when moving the workstation or handling individual c...

Page 24: ...n Right Side mm in Front mm in Behind mm in Workstation Base 202 8 153 6 153 6 Cash Drawer 330 13 7140 Printer 188 7 4 95 3 8 7158 Printer 305 12 7161 Printer 197 7 75 127 5 76 4 7194 Printer 228 9 71...

Page 25: ...Site Preparation 13 Workstation Dimensions Configuration with 2x20 Operator Display 80key keyboard 1 Line Numeric Customer Display Peripheral Tray and 2182 Cash Drawer...

Page 26: ...14 Site Preparation Configuration with Mono Passive Color LCD Operator Display 80key keyboard International VFD Customer Display with Telescope Mount Peripheral Tray and 2182 Cash Drawer...

Page 27: ...ration 15 Configuration with TFT Color LCD Operator Display 80key keyboard International VFD Customer Display with Telescope Mount Peripheral Tray and 2182 Cash Drawer 457 151 450 475 535 517 227 57 1...

Page 28: ...16 Site Preparation Configuration with 9 CRT Operator Display 80key keyboard Peripheral Tray and 2182 Cash Drawer 598 mm 450 mm 475 mm 151 mm 465 mm 400 mm 437 mm 18 mm...

Page 29: ...Site Preparation 17 Configuration with 2 x 20 Operator Display 80 Key Keyboard and 1 Line Numeric Customer Display...

Page 30: ...18 Site Preparation Configuration with 2 x 20 Operator Display 176 Key Micromotion Keyboard and International VFD Customer Display with Telescope Mount...

Page 31: ...Site Preparation 19 Configuration with Mono Passive Color LCD Operator Display 80 Key Keyboard and International VFD Customer Display with Telescope Mount...

Page 32: ...20 Site Preparation Configuration with TFT LCD Display 80key keyboard International VFD Customer Display with Telescope Mount...

Page 33: ...Site Preparation 21 Configuration with LCD Operator Display 176 Key Micromotion Keyboard and International VFD Customer Display with Telescope Mount...

Page 34: ...22 Site Preparation Configuration with TFT Color LCD Display 176 Key Micromotion keyboard and International VFD Customer Display with Telescope Mount...

Page 35: ...Site Preparation 23 Component Dimensions Base Unit with 2 x 20 Operator Display and 80 key Conventional Keyboard...

Page 36: ...24 Site Preparation Base Unit with 10 4 Mono Passive Color LCD Operator Display with 176 Key Micromotion Keyboard...

Page 37: ...Site Preparation 25 Base Unit with TFT Color Operator LCD Display and 176 Key Micromotion keyboard...

Page 38: ...26 Site Preparation Base Unit with 9 CRT Operator Display and 80 key Conventional Keyboard 355 mm 495 mm 372 mm...

Page 39: ...Site Preparation 27 245 mm...

Page 40: ...ash Drawer 15414 121 mm 4 75 in 457 mm 18 in 457 mm 18 in 277 mm 11 in Operating and Service Clearance for Drawer NCR 2189 Cash Drawer 16676 133 mm 5 25 in 330 mm 13 in 18 25 in Operating and Service...

Page 41: ...Site Preparation 29 NCR 2182 Cash Drawer...

Page 42: ...NCR 1 Line Numeric Customer Display integrated with Telescope Mount Low Profile Mount NCR 4 Line Alpha Numeric Customer Display integrated with Telescope Mount Low Profile Mount X Low Profile Mount 22...

Page 43: ...Site Preparation 31 NCR International VFD Customer Display integrated with Telescope Mount Low Profile Mount X Low Profile Mount 229 mm Telescope Mount 349mm or 424 mm...

Page 44: ...2 Site Preparation Printers 7140 Printer 15457 170 mm 6 7 in 150 mm 5 9 in 273 mm 10 75 in 245 mm 9 65 in 206 mm 8 12 in 7158 Printer 165 mm 6 50 in 336 mm 13 25 in 229 mm 9 00 in 305 mm 12 00 in 1730...

Page 45: ...Site Preparation 33 7161 Printer 148 mm 165 mm 240 mm 5 5 in 6 5 in 9 45 in 7194 Printer 16492 130 mm 5 10 in 157 mm 6 20 in 85 mm 3 30 in 212 mm 8 3 in 187 mm 7 4 in...

Page 46: ...34 Site Preparation 7196 Printer 108 mm 4 25 in 140 m 5 50 in 146 mm 5 75 in 254 mm 10 00 in 17306...

Page 47: ...ay 1 16 0 53 10 4 Passive Color LCD Operator Display 2 75 1 25 10 4 TFT Color LCD Operator Display 1 58 0 72 10 4 Mono LCD Operator Display 2 70 1 22 9 CRT Operator Display incl CRT board 8 38 3 8 1 L...

Page 48: ...ated configuration sum the weights of the appropriate individual components An example is given in the following table Workstation Components Weight lbs kg Base Unit Flash Disk Model 7 50 3 40 2182 Ca...

Page 49: ...AC power cable plugs in at the back of the base unit Power cables are described in the System Cables section Maximum Input Power Specifications Voltage Ranges 90 127 VAC 198 254 VAC Frequency 50 60 Hz...

Page 50: ...32 COM 1 RS232 COM 2 RS232 COM 6 USB 2 Ports PS 2 Keyboard Power Ethernet 10 100M Usable Cable Lengths The usable external length of all 7448 Workstation cables is less than the total length because a...

Page 51: ...Australian Power Cord 006 8601019 1416 C322 0030 3 m 9 8 ft UK Power Cord 006 8601012 1416 C321 0030 3 m 9 8 ft Power SEV Power Cord 006 8601011 1416 C320 0030 3 m 9 8 ft 497 0408349 1416 C359 0007 0...

Page 52: ...7875 Scanner Scale RS 232 497 0300422 1416 C019 0040 4 m 13 ft 7890 Scanner Module RS232 497 0405826 1416 C047 0020 2 m 6 6 ft 7890 Scanner Interface Cable 497 0410036 1416 C037 0004 0 4m 1 3 ft 7890...

Page 53: ...r 10 Pin Plug 497 0300422 7890 Presentation Scanner Cables To 7890 Scanner To 7448 Workstation 497 0405826 Scanner Module Cable 497 0410036 7890 Scanner Interface Cable 497 0300132 JAPAN 497 0300091 U...

Page 54: ...Coin Dispenser Cable Coin Dispenser 497 0404832 4 m To 7448 RS 232Port 9 pin D shell Receptacle 25 pin D Shell Plug Printer Interface Cables 7158 7194 7140 Printers Printer To 7448 RS 232 Port 9 pin...

Page 55: ...shell Plug 497 0411815 4m 1416 C417 0040 7453 K641 7194 Printer 25 pin D shell Receptacle 9 pin D shell Plug 497 0411815 4m 1416 C417 0040 NCR 7161Printer with 7453 K641 Cable Extender To 7448 RS 232...

Page 56: ...tion 0 C to 45 C 32 F to 113 F dry bulb Flash Disk Model Operating 0 C to 40 C 32 F to 104 F dry bulb Hard Disk Model Storage 10 C to 50 C 14 F to 122 F three months Shipping 40 C to 60 C 40 F to 140...

Page 57: ...Site Preparation 45...

Page 58: ......

Page 59: ...ovement of any deficiencies in power quality is a customer responsibility Malfunction and or component failure as a result of power quality problems are is not covered by the NCR Maintenance Agreement...

Page 60: ...itive indication of its failure such as a blown fuse or tripped breaker Be listed by the accepted safety organization for the country involved UL CSA VDE ETL and so on and the installation must confor...

Page 61: ...the voltage limiting type and must self recover after passage of the transient Insert less than 5 ohms resistance and minimal inductive and capacitive loading at the operating frequency for non MIRLAN...

Reviews: