44 Site Preparation
Environmental Requirements
Barometric Pressure
The 7448 Workstation is designed to operate within the following barometric
pressure conditions:
Maximum operating altitude: 2000 m (6560 ft)
Operating range of pressure: 105kPa to 79.5 kPa
Temperature
The 7448 Workstation is designed to operate over the temperature ranges shown
below. Continuous operation must be avoided, however, at or near the
temperature extremes or in locations where the temperature changes beyond the
temperature restrictions.
Temperature
Parameter
Restriction
0ºC to 45ºC (32ºF to 113ºF), dry bulb-Flash Disk Model
Operating
0ºC to 40ºC (32ºF to 104ºF), dry bulb-Hard Disk Model
Storage
-10ºC to 50ºC (14ºF to 122ºF), three months
Shipping
-40ºC to 60ºC (-40ºF to 140ºF), one week
Dew Point
26ºC (79ºF) maximum
Humidity
The 7448 Workstation is designed to operate within the humidity ranges shown
below. Continuous operation must be avoided, however, at or near the humidity
limits or in locations where the humidity changes beyond the humidity
restrictions. In no case should the 7448 Workstation be subjected to
condensation.
Humidity Type
Restriction
10% to 90%
Relative
20% to 80% (CRT Model)
Maximum change rate
10%/ 60 minutes
Storage
10% to 90 % relative humidity, three months
Shipping
5% to 95% relative humidity, one week
Summary of Contents for 7448 Workstation
Page 1: ...NCR 7448 Workstation Release 1 3 Site Preparation B005 0000 1201 Issue D...
Page 12: ......
Page 15: ...Site Preparation 3 7448 Workstation with 80 Key Conventional Keyboard...
Page 39: ...Site Preparation 27 245 mm...
Page 41: ...Site Preparation 29 NCR 2182 Cash Drawer...
Page 57: ...Site Preparation 45...
Page 58: ......