3.3
Program stop
For an immediate stop in case of operating errors, needle breakage
etc. the safety system of the 1220/5 provides the following measures:
–
Press program stop switch 2 at the control panel.
The running operations are stopped immediately.
–
Turn main switch 1 counter-clockwise.
The sewing unit drops out immediately;
all movements of the sewing unit stop immediately.
3.4
Restart after program stop
Caution: Risk of injury!
Switch the main switch off.
Clear the fault only with the sewing unit switched off.
Only restart the sewing unit after the fault has been cleared.
–
Switch on main switch 1 (turn in clockwise direction).
–
Unlock the program stop switch.
The control loads the machine program.
The basic display appears in the display of the control panel.
The sewing unit is ready for operation again.
6
2 1
2