Altering the machine parameters
Parameter 30:
Set the main speed
Setting range:
0 …7000
Parameter 31:
Switch manual sewing on or off
Setting range:
0 / 1
Parameter 32:
Time how long the table blowing remains switched on
Setting range:
0 …400 stitches
Parameter 44:
Number of stitches until the contour guide
lowers
Input:
0 …200
Parameter 60:
Softstart speed
Setting range:
500 ...5000
Parameter 61:
Switch the softstart on or off
Setting range:
0 / 1
Parameter 62:
Softstart speed
Setting range:
1 ...5000
Parameter 76:
Switch the start via light barrier on or off
Setting range:
0 / 1
Parameter 77:
Switch the autostart on or off
Setting range:
0 / 1
Parameter 78:
Number of stitches when the autostart starts
Setting range:
0 ...400 stitches
Altering the seam lines
Via this parameter the parameters for the individual seam lines are set.
Parameter 81:
Length of seam line 1
Setting range:
0 …00
Parameter 82:
Switch the speed reduction in seam line 1 on or off
Setting range:
0 / 1
Parameter 83:
Reduce the speed in seam line 1
Setting range:
0 …7000
Parameter 84:
Switch the stop within the seam on or off
Setting range:
0 / 1
Parameter 85:
Switch the sewing foot lift within the seam on or off
Setting range:
0 / 1
Parameter 86:
Seam line 2
to
Parameter 90
Values see seam line 1
Parameter 91:
Seam line 3
to
Parameter 95
Values see seam line 1
18