6.4.3
Input - Output test
Via the input - output test the different input and output elements can
be checked.
Input test
–
Press key “
P
”.
–
Press key “
8
”.
–
Actuate the corresponding input.
Example:
Cover the light barrier.
–
Press key “
Program stop
”.
The program is quitted.
Input elements
Switch
Designation
01
Light barrier 01
05
Switch “Program stop”
Output test
–
Press key “
P
”.
–
Press key “
8
”.
–
Press key “
Plus
”.
–
Select the output element to be tested with the keys “
Plus
” or
“
Minus
”.
–
Switch the output on or off with the key “F2”.
–
Press key “
Program stop
”.
The program is quitted.
Output elements
Switch
Designation
Y01
Sewing foot up / down
Y02
Thread tension lift open / closed
Y03
Contour guide up / down
Y04
Stacker off / on
Y05
Holding stamp up / down
Y06
Auxiliary roller up / down
Y12
Warp separator off / on
Y13
Table blowing off / on
Y14
Dirt suction off / on
20