PCI1040 Motion Control Card
5.5 Deceleration Stop Signal
In this case, three parameters must be set:
Parameter name
Description
Logical Direction
Positive logic and negative logic
Signal Mode
Level signal and edge signal
Movement Mode
Immediate stop and deceleration stop
In movement mode, immediate stop occurs when this command is written during drive. However, the pulse
duration of the last pulse is assured. In interpolation mode, only one axis stops. Deceleration stop: the drive
deceleration and stops when this command is written during drive. Immediate stop occurs if this command is
written during constant speed drive. However, the pulse duration of the last pulse is assured. In interpolation
mode, other axes also decelerate and stop.
BUY ONLINE at art-control.com/englishs or CALL +86-(0)10-51289836(CN)
27