Technical Description
Taste
(Cursor)
While being in the change mode (see key
), the flashing cursor is removed to the
next possible input position by actuating the key
. In some menue lines there is
only one input position available. In this case the cursor key is out of function.
Key
(Minus)
By means of this key the value to be set can be decreased. To do this change first
into the change mode.
Taste
(Plus)
By means of this key the value to be set can be increased. To do this change first
into the change mode.
Additional setting possibilities of control SV1-2-10Z
Change of access enable
There is a possibility of locking respective menue lines for inputs by the operator
resp. to unlock them. To do this one has to change into the desired menue line by
means of key
and switch the DIP-Switch S12.2 to position ON. The current status
of the access enable is displayed in this menue line.
M e n u e D : l o c k e d
Menue line
Access enable
By means of key
the menue line can now be locked or unlocked. Shall the new set
value be permanently stored this has to be confirmed by a second pressing of key
. The DIP-Switch S12.2 should then be set back to position OFF. If a menue line is
locked the operator has to enter first a 3-digit code to unlock it. In case of an incorrect
input the menue line remains locked for modifications.
Change code
To be able to change the unlocking-code the DIP-Switch S12.3 has to be set to
position ON.
N e w c o d e : 2 6 4
By means of the keys
,
and
a new code can be entered and stored by means
of key
. The DIP-Switch S12.3 should then be set back to position OFF. The code