background image

14

XENYX 1204FX/1204 User Manual

FEDERAL COMMUNICATIONS 
COMMISSION COMPLIANCE 
INFORMATION

Responsible party name: 

MUSIC Group Services USA, Inc.

Address: 

18912 North Creek Parkway, 

Suite 200 Bothell, WA 98011, 

USA

Phone/Fax No.: 

Phone: +1 425 672 0816 

Fax: +1 425 673 7647

XENYX 1204FX/1204

complies with the FCC rules as mentioned in the following paragraph:

This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed 
to provide reasonable protection against harmful interference in a residential 
installation. This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined 
by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the 

• 

receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

• 

This device complies with Part 15 of the FCC rules. Operation is subject to the 
following two conditions:

(1) this device may not cause harmful interference, and  
(2) this device must accept any interference received, including interference that may 
cause undesired operation.

Important information:

Changes or modifications to the equipment not expressly approved by MUSIC Group 
can void the user’s authority to use the equipment.

XENYX 1204FX/1204

 

Summary of Contents for XENYX 1204

Page 1: ...User Manual XENYX 1204FX 1204 Premium 12 Input 2 2 Bus Mixer with Xenyx Mic Preamps British EQs 1204FX 24 Bit Multi FX Processor and USB Audio Interface...

Page 2: ...Shipment 5 1 3 2 Initial operation 5 1 3 3 Online registration 6 2 Control Elements and Connectors 6 2 1 Mono channels 6 2 1 1 Microphone and line inputs 6 2 1 2 Equalizer 6 2 1 3 Aux sends 6 2 1 4 Ro...

Page 3: ...ability for any loss which may be suffered by any person who relies either wholly or in part upon any description photograph or statement contained herein Colors and specifications may vary slightly f...

Page 4: ...p Anyrepairoropeningoftheunitcarriedoutby 7 unauthorizedpersonnel userincluded willvoidthe limitedwarranty IfaninspectionoftheproductbyMUSICGroup 8 showsthatthedefectinquestionisnotcoveredbythe limite...

Page 5: ...tment mixing of effects frequency equalization Signal distribution Summing of signals to the aux sends for effects processing and monitor mix distribution to one or several recording tracks power amp...

Page 6: ...no input channels include a 3 band equalizer All bands provide boost or cut of up to 15 dB In the central position the equalizer is inactive The circuitry of the British EQs is based on the technology...

Page 7: ...ion in just the same way as those of the mono channels As aux send paths are always mono the signal on a stereo channel is first summed to mono before it reaches the aux bus Fig 2 4 Panorama and routi...

Page 8: ...of the effects signal routed to the monitor mix You can easily use the headphones distribution amplifier BEHRINGER POWERPLAY PRO HA4600 HA4700 HA8000 to provide you with four or eight with the HA8000...

Page 9: ...re fader and assigned to the mono PFL bus In the PFL setting only the left side of the peak meter operates Drive the individual channels to the 0 dB mark of the VU meter Solo When the MODE switch is n...

Page 10: ...s to the mixer or the stagebox wallbox Connect the microphones before you switch phantom power on In addition the monitor PA loudspeakers should be muted before activating the phantom power supply Aft...

Page 11: ...ge number of cables for the various connections to and from the console The illustrations below show the wiring of these cables Be sure to use only high grade cables strain relief clamp sleeve ring ti...

Page 12: ...A weighted 150 source resistance 129 dB 130 5 dB A weighted Frequency response 10 Hz 150 kHz 1 dB 10 Hz 200 kHz 3 dB Gain range 10 to 60 dB Max input level 12 dBu 10 dB gain Impedance approx 2 6 k bal...

Page 13: ...el fader Main mix 0 dB 95 dB 97 dB A weighted Channel fader Main Mix 0 dB 82 5 dB 85 dB A weighted Channel fader 0 dB Power supply Mains voltage 100 240 V 50 60 Hz Power consumption 40 W Fuse 100 240...

Page 14: ...that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off a...

Page 15: ...15 XENYX 1204FX 1204 User Manual...

Page 16: ......

Reviews: