3A

 1. Safety Instruction  

 

 

WARNING 

 

z

 

Please keep this User Guide for future consultation. If you sell the unit to another 
user, be sure that they also receive this instruction booklet. 

z

 

Unpack and check carefully there is no transportation damage before using the 
unit. 

z

 

Before operating, ensure that the voltage and frequency of power supply match the 
power requirements of the unit. 

z

 

The unit is designed for use with the MSD 250W. Do not use any other type of lamp. 

z

 

It’s important to ground the yellow/green conductor to earth in order to avoid 
electric shock. 

z

 

The unit is for indoor use only. Use only in a dry location. 

z

 

The unit must be installed in a location with adequate ventilation, at least 50cm 
from adjacent surfaces. Be sure that no ventilation slots are blocked. 

z

 

Disconnect main power before fuse/lamp replacement or servicing. 

z

 

Replace fuse/lamp only with the same type. 

z

 

Make sure there are no flammable materials close to the unit while operating, as it 
is fire hazard. 

z

 

Use safety chain when fixes this unit. Don’t handle the unit by taking its head only, 
but always by taking its base. 

z

 

Maximum ambient temperature is Ta : 40

. Don’t operate it where the temperature 

is higher than this. 

z

 

Unit surface temperature may reach up to 85

. Don’t touch the housing bare-hand 

during its operation, and allow about 15 minutes to cool down before replacing 
bulb or serving, as the unit could be very hot. 

z

 

In the event of serious operating problem, stop using the unit immediately. Never 
try to repair the unit by yourself. Repairs carried out by unskilled people can lead 
to damage or malfunction. Please contact the nearest authorized technical 
assistance center. Always use the same type spare parts. 

z

 

Don’t connect the device to any dimmer pack. 

z

 

Do not touch any wire during operation as high voltage might be causing electric 
shock.

 

z

   

  7. Fixture Cleaning   

 

The cleaning of internal and external optical lenses and/or mirrors must be carried out 
periodically to optimize light output. Cleaning frequency depends on the environment in which 
the fixture operates: damp, smoky or particularly dirty surrounding can cause greater 
accumulation of dirt on the unit’s optics. 

y

  Clean with soft cloth using normal glass cleaning fluid. 

y

  Always dry the parts carefully. 

y

  Clean the external optics at least every 20 days. Clean the internal optics at least every 

30/60 days. 

 

 
EC Declaration of Conformity 

 

We declare that our products (lighting equipments) comply with the following 
specification and bears CE mark in accordance with the provision of the 
Electromagnetic Compatibility (EMC) Directive 89/336/EEC. 
 

EN55014-1: 1993, EN61000-3-2: 1995, EN61000-3-3: 1995 
EN55014-2: 1997 CATEGORY II 
EN61000-4-2: 1995, EN61000-4-3: 1995, EN61000-4-4: 1995 
EN61000-4-5: 1995, EN61000-4-6: 1995, EN61000-4-11: 1994 

Harmonized Standard 

 

EN60598-1: 1993 
Safety of household and similar electrical appliances 
Part 1 : General requirements 

 
Following the provisions of the Low Voltage Directive 73/23/EEC and 93/68/EEC. 
 

EC Declaration of Conformity 

 

We declare that our products (remote controller) comply with the following 
specification and bears CE mark in accordance with the provision of the 
Electromagnetic Compatibility (EMC) Directive 89/336/EEC. 
 

EN55015: 1993 
EN50082-1: 1997 
EN61000-3-2: 1995 
EN61000-3-3: 1995 
 

 

Please read carefully the instruction, which includes important 

information about the installation, usage and maintenance. 

Summary of Contents for MOVING HEAD SPOT

Page 1: ...WWW BEGLEC COM Professional Lighting Technology User Guide Please read these instructions carefully before use ...

Page 2: ...nging rotating gobos 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2 Easy Controller 5 3 Universal DMX Controller 5 4 DMX512 Configuration 5 5 DMX512 Connection 6 Troubleshooting 7 Fixture Cleaning ...

Page 3: ...unction Please contact the nearest authorized technical assistance center Always use the same type spare parts z Don t connect the device to any dimmer pack z Do not touch any wire during operation as high voltage might be causing electric shock z 7 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleanin...

Page 4: ...it to rain or moisture z Never touch bulb with bare fingers as it is very hot after using z Hot lamp explosion hazard Do not open the unit within five minutes after switching off z Do not start on the unit without bulb enclosure or housing are damaged z The housing the lenses or the ultraviolet filter must be replaced if they are visibly damaged z Do not look directly at the light while the bulb i...

Page 5: ...ing are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connect power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link prop...

Page 6: ...nnected to the unit 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX512 system should be terminated to reduce signal errors 7 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Ne...

Page 7: ...tes at high pressure and there is a slight risk of arc tube rupture The risk increases with age temperature and improper handling of the lamp Do not use the lamp any longer than its specified life 5 Make sure the lamp is located in the center of the reflector for the best spot Adjust lamp position by screws A B and C i Channel 14 Pre programmed show pattern 1 DMX value 0 31 the fixture is still co...

Page 8: ...functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions Remote controller input By connect to the 1 4 microphone jack to control the unit for Stand by Strobe Next and Show 1 Slow Show 2 function Sensitivity To adjust the sound receiving sensitivity Microphone To receive audio signal for sound activation DMX input ou...

Page 9: ...nctions 1 STAND BY To blackout all the units 2 FUNCTION STROBE NEXT STROBE Under SHOW 1 and SHOW 2 mode the units will strobe in three different ways a Strobe in different gobos and colors b Synchronous strobe in white color c Two light strobe in white color Under SLOW mode press FUNCTION button to choose desired color and gobo It will change ten colors and then change one gobo 3 MODE SHOW 1 SLOW ...

Page 10: ...play will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button again Show Mode Press the MENU button up To when the is showing on the display Pressing ENTER button and the displa...

Page 11: ...under ceiling Press the MENU button up to when the is blinking on the display Use the ENTER button to change to the mode display inversion It will automatically store after 8 seconds Or press the ENTER button again return to the mode display normal To go back to the functions press the MENU button Display normal mode for the fixture putting on the floor Display inversion mode for the fixture fixin...

Reviews: