BEGLEC MOVING HEAD SPOT User Manual Download Page 10

 

 

10A

  5. How To Control The Unit 

 

         
You can operate the unit in three ways: 

 

1. By master/slave built-in preprogram function 

  2. By easy controller 
  3. By universal DMX controller 

 
No need to turn the unit off when you change the DMX address, as new DMX address setting 
will be effected at once. Every time you turn the unit on, it will show AE16 on the display and 
move all the motors to their ‘home’ position and you may hear some noises for about 20 
seconds. After that the unit will be ready to receive DMX signal or run the built-in programs. 

 

  5.1. Master/Slave Built-In Preprogrammed Function   

 

You can select blackout mode 

 in 

 (yes blackout) or 

 (no blackout) 

mode

 while the unit is turned on

. By linking the units in master/slave connection, the first unit 

will control the other units to give an automatic, sound activated, synchronized light show. This 

function is good when you want an instant show. You have to select 

 (show 1) or 

  (show 2) mode by easy controller. Its DMX input jack will have nothing plugged into it, 

and Its master LED will be constantly on and sound LED will flash to the music. The other 

units will have to set in slave mode 

 and select 

 (normal) or 

 (2 light 

show) mode, Their DMX cables plugged into the DMX input jacks (daisy chain) and the slave 
LED lights will constantly on. 

 

2-light show 

 

In 

 (slave  mode),

 

 

means the unit works normally and 

 

means 

2-light show. In order to create a great light show, you can set 

 

on the second unit to 

get contrast movement to each other, even if you have two units only. 
 
 
 

 
 

   

DMX512 Address Setting

 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address. 

Once the address has been selected, press the 

ENTER

 button to setup or automatically 

return to the main functions without any change after 8 seconds. To go back to the functions 
without any change press the

 MENU

 button again. 

 

   

Show Mode 

Press the 

MENU

 button up To when the 

 

is showing on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

  (show 1) or 

  (show 2) mode. Once the mode has been selected, press the 

ENTER

 button to setup 

or automatically return to the main functions without any change after 8 seconds. To go back 
to the functions without any change press the

 MENU

 button again.   

Press the MODE button from the easy controller to select the 

 (show 1) or 

 

(show 2) mode. When the LED is off, it is in SHOW 1 mode, and blinking in SHOW 2 mode 

   

Show 1 mode- Fixture is placed on the floor. Tilt movement angle 210°. 

   

Show 2 mode-Fixture is fixed under ceiling. Tilt movement angle 90°. 

 

   

Slave Mode

 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (normal) or 

  (2 light show) mode. Once the mode has been selected, press the 

ENTER

 button to 

setup or automatically return to the main functions without any change after 8 seconds. To go 
back to the functions without any change press the

 MENU

 button again. 

 

   

Blackout Mode

 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (yes 

blackout) or 

 (no blackout) mode. Once the mode has been selected, press the 

ENTER

 button to setup or automatically return to the main functions without any change after 

8 seconds. To go back to the functions without any change press the

 MENU

 button again.

 

 
 

Summary of Contents for MOVING HEAD SPOT

Page 1: ...WWW BEGLEC COM Professional Lighting Technology User Guide Please read these instructions carefully before use ...

Page 2: ...nging rotating gobos 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2 Easy Controller 5 3 Universal DMX Controller 5 4 DMX512 Configuration 5 5 DMX512 Connection 6 Troubleshooting 7 Fixture Cleaning ...

Page 3: ...unction Please contact the nearest authorized technical assistance center Always use the same type spare parts z Don t connect the device to any dimmer pack z Do not touch any wire during operation as high voltage might be causing electric shock z 7 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleanin...

Page 4: ...it to rain or moisture z Never touch bulb with bare fingers as it is very hot after using z Hot lamp explosion hazard Do not open the unit within five minutes after switching off z Do not start on the unit without bulb enclosure or housing are damaged z The housing the lenses or the ultraviolet filter must be replaced if they are visibly damaged z Do not look directly at the light while the bulb i...

Page 5: ...ing are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connect power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link prop...

Page 6: ...nnected to the unit 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX512 system should be terminated to reduce signal errors 7 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Ne...

Page 7: ...tes at high pressure and there is a slight risk of arc tube rupture The risk increases with age temperature and improper handling of the lamp Do not use the lamp any longer than its specified life 5 Make sure the lamp is located in the center of the reflector for the best spot Adjust lamp position by screws A B and C i Channel 14 Pre programmed show pattern 1 DMX value 0 31 the fixture is still co...

Page 8: ...functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions Remote controller input By connect to the 1 4 microphone jack to control the unit for Stand by Strobe Next and Show 1 Slow Show 2 function Sensitivity To adjust the sound receiving sensitivity Microphone To receive audio signal for sound activation DMX input ou...

Page 9: ...nctions 1 STAND BY To blackout all the units 2 FUNCTION STROBE NEXT STROBE Under SHOW 1 and SHOW 2 mode the units will strobe in three different ways a Strobe in different gobos and colors b Synchronous strobe in white color c Two light strobe in white color Under SLOW mode press FUNCTION button to choose desired color and gobo It will change ten colors and then change one gobo 3 MODE SHOW 1 SLOW ...

Page 10: ...play will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button again Show Mode Press the MENU button up To when the is showing on the display Pressing ENTER button and the displa...

Page 11: ...under ceiling Press the MENU button up to when the is blinking on the display Use the ENTER button to change to the mode display inversion It will automatically store after 8 seconds Or press the ENTER button again return to the mode display normal To go back to the functions press the MENU button Display normal mode for the fixture putting on the floor Display inversion mode for the fixture fixin...

Reviews: