background image

USER MANUAL – MODELS 6002NA/V1/V2/ & 7002xx

QUESTIONS?  EMAIL US AT [email protected] OR CALL 401-404-5250

WE ARE HERE TO HELP – PLEASE CALL US FOR ADVICE!

Revision 1.6 www.bedjet.com P a g e | 16

10)

If using the AirComforter, please consult the instructions

in  the  AirComforter  package  for  installation  of  the  Air

Nozzle into the AirComforter sheet.

If you are using your

own  sheets,  cover  the  Air  Nozzle  with  your  sheets  or

comforter. The  Air  Nozzle  must be  covered  by a  sheet or

comforter in order to distribute the air throughout the bed.

Twin sheet clamps are located on Mattress Mount to hold

your sheets in place over the nozzle so they are not pulled

off easily when turning over in bed.  If bedding sheets are

not typically tucked in around the nozzle, the sheet clamps are highly recommended to be

used.

11) Plug  BedJet  in AC  power  outlet  (do  not  use  power  strip)

and  switch  on.    Power  switch  is  located  directly  below

power  cord. BedJet  makes  single  beep  on  successful

power ON, and the remote control can now be used.

12) The  Remote  Control  should  already  be  synchronized  with

BedJet  on  delivery.    However,  if  pressing  remote  control

center  buttons  does  not  activate  BedJet  after  power  ON,

try  synchronizing  the  Remote  Control  per  instructions  on

page 11. If still not working, replace the battery.

13) Familiarize yourself with turning on and off the various operating modes while the Status

Display of BedJet is visible before the BedJet is pushed under the Bed.

14) The ideal BedJet final installation location is under the bed.  This product is designed to be

an  extension  of your bed  and  has  been  electrically
approved as safe for this installation.   The BedJet requires
7  inches  clearance  and  will  fit  under  nearly  all  beds  with
standard frames.  Some bedframes with low hanging side
rails may look like they cannot fit the BedJet underneath,
but  this  is  just  the  side  rail  and  the  under  mattress  area
may still have 7 inches height clearance. In these cases,
the  bed  frame  may  be  lifted  up  and  the  BedJet  placed
underneath.   As long as the mattress or frame does not rest on the BedJet and the 3”
hose can clear the low side rail, the installation is acceptable.

15) When installing under the bed, adjust the location of the BedJet exhaust port to be as

close as possible to the Air Nozzle. Best location is for the exhaust port to be directly
under the Air Nozzle so that it can be reached with only a single 90 degree bend in hose.
The best setup will minimize the length of Air Hose and minimize the number of bends.

Summary of Contents for 6002NA V1

Page 1: ... for residential home use only It is not intended to be used in commercial industrial or human medical settings READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DESCRIBED PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETYINFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN...

Page 2: ...s which are delightful therapeutic and luxurious Along the way we believe it is also possible to build a profitable company while doing right by our customers and showing them love and appreciation We want to be a company that deals with each of our customers as if they were our neighbors We also understand that the BedJet is a luxury product and that there are many in the world who cannot afford ...

Page 3: ...NOT OPERATE MORE THAN ONE BEDJET ON SAME BEDROOM AC POWER CIRCUIT WITHOUT ADJUSTING DUAL MODE SWITCH LOCATED ON REAR OF DEVICE TO DUAL ZONE ON LOW POWER FOR REDUCED POWER OR DEVICES MAY EXCEED CIRCUIT BREAKER CAPACITY AND CAUSE POWER DISTRUPTION OR ELECTRICAL HAZARD 7 This appliance has a polarized plug one blade is wider than the other To reduce the risk of electric shock this plug is intended to...

Page 4: ... arcing or sparking parts inside Do not use the BedJet in areas where gasoline paint or flammable liquids are used or stored It must NOT be used in potentially dangerous locations such as flammable explosive chemical laden or wet atmospheres This device is intended for residential bedroom use ONLY 15 This device is not intended for use in wet or damp locations This device is NOT INTENDED for use i...

Page 5: ...aged from 3 years and less than 8 years shall not plug in regulate and clean the appliance or perform user maintenance 25 Children should be supervised to ensure that they do not play with the appliance 26 CAUTION Some parts of this product can become very hot and cause burns Particular attention has to be given where children and vulnerable people are present 27 Heater must not be located immedia...

Page 6: ...uble insulated product nor is a means for grounding to be added to the product Servicing a double insulated product requires extreme care and knowledge of the system and is to be done only by qualified service personnel Replacement parts for a double insulated product must be identical to the parts they replace A double insulated product is marked with the words DOUBLE INSULATION or DOUBLE INSULAT...

Page 7: ... room air conditioning in extremely hot climates and may not be highly effective if room ambient temperatures are over 80 F 27 C Heating of the airflow in the base unit is achieved via a unique patent pending ceramic stone heating element These advanced technology ceramic stone heating elements have been specially engineered to gently heat the air flow while maintaining internal element surface te...

Page 8: ...air intake filter Pre Installation Checklist Before attempting installation of the BedJet please verify the following standard parts list from your BedJet package Adjustable height mattress mount with qty 2 pre installed sheet clamps and qty 4 height extending links Air Nozzle BedJet base unit Radio wireless remote control with A23 alkaline battery 1 Air Hose with fabric liner stretchable compress...

Page 9: ... Requirements for the top sheet or comforter are very simple just use any bedding material type cotton cotton blends microfiber etc with a 250thread count weave or higher Alternatively the BedJet AirComforter accessory may be used as a replacement for a typical top sheet or comforter see Dual Zone Installation Use of loosely knit low quality top sheets with thread count below 250 or loose knit top...

Page 10: ...orange Power ON LED on the BedJet Status Display see below will light This signifies the BedJet is in stand by mode and ready to accept commands from the wireless remote control or link to a Bluetooth enabled smart device The BedJet uses very little power when in standby mode BedJet Status Display Located on top of the BedJet the Status Display gives information on current mode setting of the BedJ...

Page 11: ...remote control buttons are pressed verified by LED indicator on remote but the BedJet does not activate then re pair the remote control to BedJet with the following procedure To pair your remote control to your BedJet make sure BedJet is powered OFF for 10 seconds Turn BedJet switch ON while simultaneously pressing and holding the COOL Button on remote control until the BedJet Power ON indicator l...

Page 12: ... heating power by approximately 50 in the Turbo heat mode and 20 in regular heat mode in order that two BedJet s being used simultaneously on the same AC bedroom circuit will not exceed AC circuit capacity This is still plenty of power to warm the bed quickly Installations where only one BedJet is used on the same household branch AC Circuit and one BedJet device is installed on the bed should set...

Page 13: ...ill until it snaps back in place Installation Single Zone BedJet Use the following instructions for a single zone BedJet installation A single zone BedJet installation is a single BedJet installed on any size bed resulting in heating or cooling of the entire bed as a single temperature zone Settings on medium or low may allow only half sections of the bed to be heated or cooled if desired see Step...

Page 14: ...Comforter please consult instructions found in the AirComforter package available Nozzle locations will be different than shown below 4 Locate parts for adjustable Hose Mattress Mount assembly The adjustable Hose Mattress Mount comes in multiple pieces Whole bed warming and cooling slightly favors left side on low air settings best Mostly left side of bed warming and cooling Mostly right side of b...

Page 15: ...inst the mattress 7 Assemble Air Nozzle onto the Air Hose Stretch and compress the Air Hose note how it can be expanded contracted and bent to retain any desired shape 8 Push the fabric section of Air Hose onto Mattress Mount Hose Grip Grip will stretch open to accept the hose Remove or add Mattress Mount Height Extending Links to adjust height of the Hose Grip so that bottom of the Air Nozzle res...

Page 16: ...ivate BedJet after power ON try synchronizing the Remote Control per instructions on page 11 If still not working replace the battery 13 Familiarize yourself with turning on and off the various operating modes while the Status Display of BedJet is visible before the BedJet is pushed under the Bed 14 The ideal BedJet final installation location is under the bed This product is designed to be an ext...

Page 17: ...ot crush either component This may require fully extending the Air Hose to move BedJet further away from the Air Nozzle Mattress mount location than shown here HELP CAN T FIT THE BEDJET UNDER THE BED For situations where the BedJet cannot fit under the bed we offer the vertical mount BedJet stand that allows you tuck the BedJet neatly against the foot of the bed out of the way and taking up a tiny...

Page 18: ...mode OFF command While active in any given cooling heating mode pressing a different mode button will switch cooling heating modes without shutoff of the BedJet The BedJet will beep once to indicate the mode change Please note when changing from heating to cooling mode it will take some number of minutes for the air exhaust temperature to become cool Adjust the Air Flow using the or buttons on the...

Page 19: ...er Enjoyment Cooling mode has a default Auto Shutoff time of 10 hours The first press of the hourglass button on the wireless remote will reduce the default Auto Shutoff time to 30 minutes and then each additional press of the hourglass button shall increase time by an additional 30 minutes The BedJet cools you via powered ventilation of fresh ambient temperature air directly into the bed This pow...

Page 20: ...rally 250 thread count or higher to keep the cooling air trapped and circulating in the bed This condition results from use a top sheet that is not compatible with the BedJet or use of no top sheet at all and just a loose knit blanket At 100 airflow your bed should have nearly all of your bedding ballooning slightly off the bed and air flow will be felt exiting at the very top of the bed from unde...

Page 21: ...f your bedding by up to 30 F 17 C above ambient in just five minutes This mode has a very short default Auto Shutoff time of 5 minutes as the warmth generated and noise levels are too powerful for extended use or comfortable sleeping Each press of the hourglass button on the wireless remote will extend Auto Shutoff by 1 additional minute to maximum of 10 minutes Do not continuously re cycle the Be...

Page 22: ...he BedJet heating modes can lower the local humidity in the bed For individuals who suffer from dry itchy skin in the winter extended duration use of the BedJet heating while in bed may contribute to the dryness Use moisturizer your partner will love your soft skin or better yet use the BedJet as a toasty pre heater before getting in bed or short burst heat when needed while in bed rather than for...

Page 23: ...Pad iPod Touch Download the BedJet App from the iTunes Store Once the BedJet is powered on run the BedJet App and press the blue window on the bottom left of main screen that says Pair On following screen press Search the local BedJet device should show up on the list Press the device ID and the pairing should begin The Bluetooth symbol on the BedJet Status Display will light once the Bluetooth li...

Page 24: ...hnology features Aromatherapy Accessory Kit Optional aromatherapy diffuser kits are available for the BedJet These kits provide a convenient means for diffusing essential oils into the air exhaust of the BedJet The aromatherapy kit consists of Qty 8 essential oil diffuser strips 1 x 3 long black foam and a spring clip for mounting the diffuser strips inside of the BedJet air nozzle 1 Place 3 5 dro...

Page 25: ...h a BedJet the AirComforter looks wonderfully puffy luxurious and down filled but it s actually only filled with conditioned air from the BedJet making it one of the softest and lightest comforters ever created The AirComforter sheet can be used in the following configurations Single BedJet One BedJet is installed on the bed and the BedJet s heating and cooling power is directed to mostly that hal...

Page 26: ...reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful ...

Page 27: ...s normal operation 3 Beeps Remote control learning pairing function has been successfully accomplished This indicates successful learning pairing of a remote control to the BedJet Remote control has not been learned if 3 beeps are not made 4 Beeps User is over cycling the Turbo Heat mode by running it more than 10 minutes out of every 30 minutes This over cycling is caused by turning the Turbo Hea...

Page 28: ...her LED lights are off and unit will no longer operate BedJet beeps 5 times The BedJet microprocessor has discovered a monitoring error within the system This does not always mean your BedJet is malfunctioning and typically may occur if you rapidly change modes or airflow while at the same time obstructing inlets or outlets The number of blinks the Power LED shows is an error code Shut the BedJet ...

Page 29: ...omforter accessory DUAL ZONE AIRCOMFORTER BedJet is on but it s not cooling or heating very well Check to make sure Air Nozzle is properly installed with AirComforter they can shift and move over time Make sure AirComforter elastic opening is fully installed around Air Nozzle and pulled down as far on the Air Hose as possible The Air Comforter elastic opening should be reaching the sheet clamps Be...

Page 30: ...s warranty is conditioned upon proper use of the product by the purchaser Any problem with the product that is caused by abuse misuse and operation contrary to or inconsistent with the written instructions or an act of God such as a flood is not covered BEDJET LLC does not have any obligations if our inspection reveals that the product has been altered modified damaged subjected to or involved in ...

Reviews: