background image

IMPORTANT INSTRUCTIONS

USER OPERATING MANUAL – MODEL 1222NA/2222EU

Revision 1.0

P a g e | 13

Certifications

The BedJet VET has been designed to operate as a safe forced air heating extension for animal
beds.  This product has been rigorously tested by an accredited 3

rd

party testing lab to be

qualified as a safe electric appliance. The BedJet complies with the following safety and
product standards:

Underwriters Laboratories 499 (BedJet VET Model 1222NA)

Canada CSA Standard 22.2 No 64 (BedJet VET Model 1222NA)

CE (BedJet VET Model 2222EU)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.

Consult the dealer or an experienced radio/TV technician for help

.

Warning:  Changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the
device.

Summary of Contents for 1222NA

Page 1: ...ly It is not for use in any human household or human medical application READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DESCRIBED PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE ...

Page 2: ...d to fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician Do not attempt to defeat this safety feature 6 DO NOT plug device into any other cord connected device such as a power strip surge protector multiple outlet adapters or outlet type air fresheners The use of such devices may create a fire...

Page 3: ... device has hot and arcing or sparking parts inside Do not use the BedJet in areas where gasoline paint or flammable liquids or flammable gases are used or stored It must NOT be used in potentially dangerous locations such as flammable explosive chemical laden or wet atmospheres 15 This device is not intended for use in wet or damp locations This device is NOT INTENDED for use in bathrooms laundry...

Page 4: ...t not be located immediately below a socket outlet 23 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard WARNING REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS DEVICE WITH ANY SOLID STATE SPEED CONTROL DEVICES SAVE THESE SAFETY INSTRUCTIONS MANUFACTURER INFORMATION BEDJET LLC 217 Goddard Row N...

Page 5: ... All parts included are required to be fully assembled and installed onto the BedJet as part any operation Do not operate the BedJet without the included Air Hose Do not attempt to use the BedJet with air delivery accessories or air delivery components not approved or supplied by BEDJET LLC Air Hose with fabric liner stretchable compressible and bendable BedJet VET and pre installed HEPA filter Ra...

Page 6: ...ately 800 watts Use the LOW POWER setting only if two BedJet units are plugged into the same outlet or other high power devices are connected to the same outlet causing concerns about electrical outlet overloading BedJet VET Wireless Remote Control All BedJet Veterinary operating modes are activated via the Wireless Remote Control or a Bluetooth connected smartphone or tablet using the BedJet Vete...

Page 7: ...ontrol until BedJet Power ON indicator lights BedJet will make 3 fast beeps to indicate successful pairing to remote Only one remote can be paired to a BedJet base unit at any given time The pairing is permanent until a new remote control is paired BedJet VET Status Display Regular Display Messages Power LED ON System ready Heat Mode LED ON Unit within 1 5 C of temperature set point Heat Mode LED ...

Page 8: ...ure mode button on the remote once A single beep confirms an ON command Deactivate BedJet into standby by pressing the same temperature mode button again A double beep confirms a mode OFF command While active in any given heating cooling mode pressing a different mode button will switch heating cooling modes without shutoff of the BedJet The BedJet will beep once to indicate the mode change Adjust...

Page 9: ...5 minutes 4 Hours Cool Room temperature 1 hour 30 minutes 12 hours HEATING MODES IMPORTANT NOTES Regulated Air Output Temperature is 1 5 C at end of hose Basic heat mode functions are available via the wireless remote control Advanced heat mode functions can be accessed via the BedJet Bluetooth smart remote App including Bluetooth Smart Remote App USE THE APP UNLOCK ADVANCED FUNCTIONS NOT AVAILABL...

Page 10: ...ch the local BedJet device should show up on the list Press the device ID and the pairing should begin The Bluetooth symbol on the BedJet Status Display will light once the Bluetooth link is active with your smart device iOS iPhone iPad iPod Touch IMPORTANT INSTRUCTIONS IN BOLD Download the BedJet VET app from the iTunes Store search under VET Warmer Do not download the regular BedJet app this is ...

Page 11: ...r intake grill until it snaps back in place HEPA FILTER REPLACEMENT The HEPA filter is recommended to be replaced every 400 hours or every 6 months of regular use The BedJet contains a HEPA filter service clock At 400 hours the BedJet will give a service alarm notification via rolling green LED on the air flow indicated accompanied by beeping when in standby HEPA FILTER SERVICE ALARM RESET Turn Be...

Page 12: ...s o Air exhaust measured at 46 C for 120 seconds o Air exhaust measured at 53 C for 12 seconds o Air exhaust measured at 55 C for 1 second Mechanical thermostatic overheat switch located in air exhaust that will shut off power to the heater as redundant safety feature to microprocessor monitoring failure Specifications Voltage 120V for BedJet VET Model 1222NA 220 240V for BedJet VET Model 2222EU P...

Page 13: ...n This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turnin...

Page 14: ...n Recommendation 1 Beep BedJet switched on Cooling heating mode ON command received from the remote control or App Air Flow increase decrease command received from remote control or App This is normal operation 2 Beeps Cooling heating mode OFF command received from the remote control or App This is normal operation 3 Beeps Remote control learning pairing function has been successfully accomplished...

Page 15: ... mean your BedJet is malfunctioning and typically may occur if you rapidly change modes or airflow while at the same time obstructing inlets or outlets Over temperature problem Check to make sure air filter is clean and there are no air inlet or outlet obstructions Shut the BedJet off for 10 seconds and restart Run in cool mode for 2 minutes and then retry heating mode If this does not solve the p...

Page 16: ...product by the purchaser Any problem with the product that is caused by abuse misuse and operation contrary to or inconsistent with the written instructions or an act of God such as a flood is not covered BEDJET LLC does not have any obligations if our inspection reveals that the product has been altered modified damaged subjected to or involved in an accident disassembled repaired or attempted to...

Reviews: