Function Table List:
Setting Functions Setting
Functions
00
AC Drive Operational
13
Top Count Value Attained
01
Maximum Output Frequency
Attained
14 Preliminary
Counter
Value
Attained
02 Zero
speed
15
Warning (PID feedback loss,
communication error)
03
Over-Torque detection
16
Below the Desired Frequency
04
Base-Block (B.B.) Indication
17
PID supervision
05
Low-Voltage Indication
18
Over Voltage supervision
06
AC Drive Operation Mode
19
Over Heat supervision
07
Fault Indication
20
Over Current stall supervision
08
Desired Frequency attained
21
Over Voltage stall supervision
09
PLC Program Running
22
Forward command
10
PLC Program Step Completed
23
Reverse command
11
PLC Program Completed
24
Zero Speed (Includes Drive Stop)
12
PLC Operation Paused
Function Explanations:
00
AC Drive operational:
terminal output is activated when there is power output from
drive.
01
Maximum Output Frequency Attained:
terminal output is activated when the AC
drive attains Maximum Output Frequency.
02
Zero speed:
terminal output is activated when Command Frequency is lower than the
Minimum Output Frequency.
03
Over-Torque Detection:
terminal output is activated when over-torque is detected.
Parameter Pr.61 determines the Over-Torque detection level.
04
Base-Block (B.B.) Indication:
terminal output is activated when the AC drive output is
shut-off by the external Base-Block.
05
Low Voltage Indication:
terminal output is activated when low voltage is detected.
06
AC Drive Operation Mode:
terminal output is activated when the operation of AC
Drive is controlled by External Control Terminals.
07
Fault Indication:
terminal output is activated when certain faults occur (oc, ov, oH, oL,
oL1, EF, cF3, HPF, ocA, ocd, ocn, GF).
08 Desired
Frequency
Attained:
terminal output is activated when the desired frequency
(Pr.47) is attained.
B550
Series
sensorless vector frequency drive
Summary of Contents for B550-2001
Page 1: ...B550 Series Sensorless Vector Frequency Drive Installation Quick Start Manual ...
Page 2: ......
Page 6: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Page 8: ...1 2 1 4 External Parts and Labels B550 Series sensorless vector frequency drive ...
Page 20: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Page 26: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Page 92: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Page 94: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Page 100: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Page 116: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...