Example:
Pr. 152
Skip Frequency Width
Factory Setting: 0.00
Settings 0.00 to 400.00Hz
Pr. 153
Bias Frequency Width
Factory Setting: 0.00
Settings 0.00 to 400.00Hz
Frequency
of
Δ
top point F
up
= master frequency F + Pr.152 + Pr.153.
Frequency of
Δ
down point F
down
= master frequency F – Pr.152 – Pr.153.
Fup
Fdown
Pr.10, 12
Pr.11, 13
Pr.152
Master
Frequency
(F)
Double Pr. 153