Commissioning and configuration
EP9300-0022
37
Version: 2.3
PROFINET record data
(read request)
Value
Meaning
Slot
Position of the EtherCAT device
(1...255)
Slot number, position of the EtherCAT
device
SubSlot
1
Sub-slot number, always "1"
Index
0x200F
PROFINET index number
Length
Write
0
Response
4
Length of the following data
Data
Write
-
Write
ADS error code
CoE data
The response to the read request, i.e. the read response, includes confirmation that writing was
successful. The first 4 bytes contain the error code; "0" indicates error-free response. The error code is an
ADS error code. Further information can be found under the following link.
http://infosys.beckhoff.com/content/1031/tcsample/html/ads_returncodes.htm
Observe data format
During reading and writing, observe the data size and the format of the corresponding SDO param-
eters. We recommend reading the SDO data first, then interpret them and use the read data format
also for writing the CoE data (perhaps swap High/Low BYTE/WORD).
Start-up parameters overwrite COE data
CoE data are typically not stored in the EtherCAT device. Make sure that the CoE data are overwrit-
ten again by the Start-up parameters (GSDML) when starting the EP9300-0022.