Commissioning
EL47xx
154
Version: 2.7
Special oversampling factor and Shift Time for the SYNC0 pulse
CAUTION
CAUTION! Risk of device damage!
If these settings are changed in the System Manager, no plausibility checks are carried out on the software
side. Correct function of the terminal with all conceivable setting options cannot be guaranteed.
To set an oversampling factor that is not listed in the dialog, the ratio between SYNC0 and SYNC1 pulse can
be set manually. Open the "Advanced Settings" dialog in the DC tab (Fig.
DC tab, activation „Advanced
Settings…“, TwinCAT 2.10 and TwinCAT 2.11
).
A local shift time for offsetting several EL47xx devices can also be set here (Fig.
DC tab, activation
„Advanced Settings…“, „Distributed clocks“
).
Fig. 192: DC tab, activation „Advanced Settings…“, TwinCAT 2.10
Fig. 193: DC tab, activation „Advanced Settings…“, TwinCAT 2.11