Setting the limit positions using the programming unit
Setting the limit positions
There are
4
ways to set the limit positions:
•
Upper stop to lower stop
•
Upper point to lower point
•
Upper stop to lower point
•
Upper point to lower stop
The limit position becomes fixed after the tubular drive has turned off
automatically
in the desired position three times.
If the tubular drive switches off prematurely while opening or closing, due to an obstruc-
tion, the obstruction can be cleared by reversing a short way and removing the obstruc-
tion. The desired limit position can be set by opening/closing again.
Attention
The switch is not suitable for continuous operation and has only been designed for start-
up.
Programming setting
Switch
Delete setting
Direction arrows
Programming button
Travel button
Connect the wires of the tubular drive to those of the same colour in the programming
unit (Item No. 4935 200 011 0) and switch on the power supply.
Upper stop to lower stop
Set both switches to the programming setting.
Open as far as the permanent upper stop.
▻
The tubular drive switches off automatically.
Move down to the lower limit position.
▻
The tubular drive switches off automatically.
►
The limit positions are now set.