Lower point to upper point without stops
There is no shading solution length adjustment with this limit position setting.
Set both switches to the programming setting.
Open to the desired upper limit position.
Press the programming button of the programming unit for 3 seconds.
▻
The tubular drive makes a “click” sound to confirm.
Then close to the desired lower limit position.
Press the programming button of the programming unit for 3 seconds.
▻
The tubular drive makes a “click” sound to confirm.
►
The limit positions are now set.
Upper stop to lower point
Set both switches to the programming setting.
Open as far as the permanent upper stop.
▻
The tubular drive switches off automatically.
Then close to the desired lower limit position.
Press the programming button of the programming unit for 3 seconds.
▻
The tubular drive makes a “click” sound to confirm.
►
The limit positions are now set.