background image

29

Summary of Contents for E01 Series

Page 1: ...ular drives for roller shutters Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com ...

Page 2: ...ecuring the drive against axial displacement 10 Fixing the drive adapter to the barrel dia 35 and dia 45 10 Mounting the drive in the tube 10 Setting the limit positions with switches 12 Deleting the limit positions using the switches 14 Setting the limit positions using the programming unit 15 Deleting the limit positions using the programming unit 18 Adjusting the limit positions with a rotary s...

Page 3: ...sive range of the drive manufacturer s control units For plug in connecting cable Please observe these Assembly and Operating Instructions when installing and setting the equipment The date of manufacture comes from the first four digits of the serial number The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week Example 24th calendar week in 2012 Ser No 1224XXXXX ...

Page 4: ...nstructions in EN 60335 2 97 Please note that this list of safety instructions is not exhaustive since it would be impossible for the standard to include all sources of danger For example the design of the operated product the way the drive works in the situation it is installed in or even the way the end product is mounted in the end user s place of use cannot be taken into consideration by the d...

Page 5: ...its are operated certain components e g the power supply unit are live Physical injuries or damage to property can result in the event of unauthorised interventions or failure to heed warnings Be careful when touching the tubular drive as it heats up during operation for technolo gical reasons Before installation shut down all lines and control devices that are not essential for op eration Crushin...

Page 6: ...s and others since these ac tions can impair the system s safety and carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or injury arising from such actions Always observe the information in these instructions when operating or repairing the system The drive manufacturer does not ac cept liability for damage or injury resulting from im...

Page 7: ...the connecting cable must be disconnected On drives with a diameter Ø35 insert a suitable flathead screwdriver between the locating lug and the snap in pin so that the snap in pin releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver Ø35 A A snap in pin 7 ...

Page 8: ...onnecting cable must be disconnected On drives with a diameter Ø45 or Ø58 insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver dia 45 and dia 58 1 2 A A locating latch 8 ...

Page 9: ... bracket Then mount the wall bracket and idler Ensure that the barrel is aligned at right angles to the wall and that sufficient axial play is al lowed for the mounted system Attention When using anti lifting devices closed brackets must be fitted The tubular drive presses the closed curtain down to make it difficult for people to reach under it or raise it Only use curtains made of sufficiently s...

Page 10: ... 40 mm plastic drive adapter 13 Self tapping screw dia 4 8 x 9 5 mm dia 45 50 70 mm plastic drive adapter 25 Self tapping screw dia 4 8 x 9 5 mm dia 45 50 85 mm plastic drive adapter for obstacle detection 40 Self tapping screw dia 4 8 x 9 5 mm dia 45 50 85 mm diecast drive adapter 50 Self tapping screw dia 4 8 x 9 5 mm We also recommend screwing the idler to the barrel Attention Do not hammer the...

Page 11: ...sembled unit comprising barrel tubular drive and idler on the box and secure the drive with a split or spring pin ac cording to the type of wall bracket fixing Position the barrel so that the roller shutter curtain can be attached with springs or fit the anti lifting devices in accordance with the manufacturer s instructions When using springs anti lifting devices we recommend you use at least thr...

Page 12: ...t position can be set by opening closing again Attention The switch is not suitable for continuous operation and has only been designed for start up Programming setting Switch Delete setting Direction arrows Connect the wires of the tubular drive to those of the same colour in the switch Item No 4901 002 181 0 or operator control and switch on the power supply Upper stop to lower stop Set both swi...

Page 13: ... the switch of the DOWN direction of rotation from the delete setting to the pro gramming setting The limit positions are now set Upper point to lower stop There is no shading solution length adjustment with this limit position setting Set both switches to the delete setting Execute a short drive command Open to the desired upper limit position Now reset the switch of the UP direction of rotation ...

Page 14: ...stops has been programmed with the switches Reset the switch of the corresponding limit position from the programming setting to the delete setting Execute a short drive command The limit position is now deleted Deleting both limit positions Reset both switches from the programming setting to the delete setting Execute a short drive command Both limit positions are deleted 14 ...

Page 15: ...and removing the obstruc tion The desired limit position can be set by opening closing again Attention The switch is not suitable for continuous operation and has only been designed for start up Programming setting Switch Delete setting Direction arrows Programming button Travel button Connect the wires of the tubular drive to those of the same colour in the programming unit Item No 4935 200 011 0...

Page 16: ...o the desired lower limit position Press the programming button of the programming unit for 3 seconds The tubular drive makes a click sound to confirm The limit positions are now set Upper stop to lower point Set both switches to the programming setting Open as far as the permanent upper stop The tubular drive switches off automatically Then close to the desired lower limit position Press the prog...

Page 17: ...n to the desired upper limit position Press the programming button of the programming unit for 3 seconds The tubular drive makes a click sound to confirm Then move down to the lower limit position The tubular drive switches off automatically The limit positions are now set 17 ...

Page 18: ...eletion sequence Deleting a limit position when 2 limit positions are programmed black brown blue green yellow black brown blue green yellow Programming button Travel button Open close to the limit position to be deleted Press the programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button but continue to keep the travel button pr...

Page 19: ...es the limit position Stop permanently once the it has been reached 3 times in succession Installation is then com plete There are 4 ways to set the limit positions Upper stop to lower stop Upper point to lower point Upper stop to lower point Upper point to lower stop The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times If the tu...

Page 20: ...tion between the individual drive commands The tubular drive makes a click sound to confirm 1 s 1 s until STOP and hold until Then close to the desired lower limit position Carry out the following sequence without interruption between the individual drive commands The tubular drive makes a click sound to confirm 1 s 1 s until STOP and hold until The limit positions are now set Upper stop to lower ...

Page 21: ...Both limit positions are deleted Upper anti freeze mechanism The upper anti freeze mechanism helps to prevent the roller shutter from freezing in the upper limit position as the roller shutter stops just before the upper stop The distance from the upper stop is automatically cyclically checked and if necessary correc ted The upper anti freeze mechanism is deactivated on delivery Both limit positio...

Page 22: ...n the area of the upper limit position it checks once more whether an obstacle is present To ensure complete closing of the roller shutter curtain at the lower limit position the curtain does not reverse once it gets to ap prox 360 from the lower limit position Moving UP Extremely large increase in the load e g ice on the end strip To ensure that the roller shutter curtain safely enters the guide ...

Page 23: ... when drives with electronic and mechanical limit switching are used in the same system The changeover time for switching the running direction must be at least 0 5 s The switch and control must not execute simultaneous UP and DOWN com mands Protect the electrical connections from damp Once you have finished wiring everything to the control ALWAYS check the right direction assignment of the drive ...

Page 24: ...ameter mm 37 Emission sound pressure level dB A 70 Technical data dia 45 Model R8 E01 R12 E01 R20 E01 R30 E01 R40 E01 Type R8 17C PRO R12 17C PRO R20 17C PRO R30 17C PRO R40 17C PRO Rated torque Nm 8 12 20 30 40 Output speed rpm 17 Limit switch range 64 revolutions Supply voltage 230 V AC 50 Hz Connected load W 100 110 160 205 260 Rated current consumption A 0 45 0 50 0 75 0 90 1 15 Mode S2 4 min ...

Page 25: ...reset button on the programming unit No click ing sound emergency program tubular drive can be opened and closed for dis mounting using the programming unit Tubular drive switched off the last time it went in that direction because of a block age Clear and remove the blockage and set the drive in the direction required Electrical connection faulty Check the electrical connection When you attempt t...

Page 26: ...lack and brown wires according to the direction of travel is de pendant on how the drive is installed mounted to the right or to the left Controlling one several drive s via a single switch button Controls black brown blue green yellow Controls 26 ...

Page 27: ...dual control using Centronic UnitControl UC42 Mains 230 V 50 Hz Central Group Individual Individual 230 V 50 Hz Central cable connection to further control units 230 V 50 Hz 230 V 50 Hz Electronics 230 V 50 Hz Control unit 27 ...

Page 28: ...Declaration of conformity 28 ...

Page 29: ...29 ...

Page 30: ...30 ...

Page 31: ...31 ...

Page 32: ...2010 300 624 0c 02 10 2015 ...

Reviews: