Connect the machine to the electric network, which must be equipped with line
fuses, the proper ground plate in compliance with OSHA regulations and it must be
connected to an automatic circuit breaker (differential) set at 30 mA.
Should the user need to provide a different electric plug, please ensure that it is rated
at least for 16 Amps.
4.4
OPERATING TESTS
•
When pedal (Z) is pressed down the turntable (Y) should turn in a clockwise direction. When
pedal is pulled up the turntable should turn in an anticlockwise direction.
If the turntable turns in the opposite direction to that shown, reverse two of the
wires in the tree-phase plug.
•
Pressing the pedal (U) activates the bead
breaker (R); when the pedal is released the bead
breaker returns to its original position.
•
Pressing the pedal (V) opens the four clamps
(G); when the pedal is pressed again, they close.
•
Pressing the trigger on the airline gauge, will
cause air to be released from the head.