FACTORY VALUES
* For more information about installation, please refer to Application Note (AN).
7
MOUNTING
SIDE
right
left
The scanner can be configured at left side and right side.
Please note that the sensor will automatically find the mounting side during the teach-in process
*
.
After finishing teach-in process, use remote control to change the parameter if needed. This
parameter must be defined before setting the configuraiton, as the detection area will link to this
parameter.
W
H
W
H
left
right
Parameter Setting (
Optional
)
Please always make sure that the mounting side you adjusted is same as the actual one on site.
* Learn more about the Teach-in, please see page 12
TEACH-IN
TEACH-IN
setting the field 1&2 through Teach-in*
3s
3s
max 30s
DETECTION
FILED
Detection area: detection will only happen when objects locate in the detection area. The
dimension of detection area could be adjusted by adjusting the parameter.
Please note that the detection range can be guaranteed with 5% reflectivity @4m diagonal
when fog filter value is set to 0, if the fog filter value is not 0, then the guaranteed detection
distance will be shortened with 5% reflectivity.
*
400
cm
0 - 550 cm
W
FI
EL
D
1
400
0 - 550 cm
W
FI
EL
D
2*
cm
Parameter Setting (
Optional
)
7