5
VIII. HOW TO USE THE REMOTE CONTROL
30 minutes after last use, the scanner locks the access to the remote control session.
Cut and restore power supply. The remote control session is accessible again during 30 minutes.
Before use the remote control, please check the following points:
1. The effective control distance is 4 meters, please always use remote control within 4 meters of the scanner.
2. The scanner curtain should not be perpendicular to the high reflective surface, a 3-degree angle in between is
necessary to guarantee communication between the scanner and the remote control.
3. To avoid unexpected operation, the authorized operator or installer could set a password to get into the parameter setting
process.
After unlocking, the red
LED flashes and the scanner
can be adjusted by remote
control.
If the red LED flashes quickly after unlocking, you
need to enter an access code from 1 to 4 digits.
To end an adjustment session,
always lock the scanner.
ADJUSTING ONE OR MORE PARAMETERS
x
CHECKING A VALUE
4
2
1
= field width: 4.2 m
X = THE NUMBER OF FLASHES INDICATES THE VALUE OF THE PARAMETER
x
RESTORING TO FACTORY VALUES
The access code is recommended for scanners installed close to each other.
teach-in
SAVING AN ACCESS CODE
DELETING AN ACCESS CODE
* Please complete this setting within 1 minute after power on.
* Setting will take effect 1 minute later.