6
IX. PARAMETER SETTINGS
(1)
(2)
(3)
(4)
(5)
(6)
(12) Detection field 1 (W)
(13) Detection field 2 (W)
(15) Check Values
(16) Lock
(17 Output configuration
(19) Multifunction key * 2
(7)
(8)
(9)
(10)
(11)
* 1
(14) Uncovered zone
(18) Antimasking & Background
(20) Immunity filter
(21) Detection mode
(22) LED activation
* 1. Mounting side: right
* 2. Match with other keys to change among different
functions
VISIBLE
SPOTS
turn on /off the visble spots
- Confirm the wiring of the scanner.
- Power on.
- Switch on the visible spots, then align the curtain position precisely (refer to remote control instruction).
- Adjust the tilt angle to make sure the curtain covers the detection area approximately if necessary.
- The shape of laser spot is oval, the further the laser spot shoots, the bigger the spot diffuses, refer to
below diagram to calculate the size, avoid unwanted detections.
ALIGNMENT
Visible spot
Laser beam
43mm
21.5mm
Distance (m)
b (mm)
a (mm)
1
12.5
1.5
2
25
3
3
37.5
4.5
4
50
6
5
62.5
7.5
a=width
b
=
hei
gh
t
Do not look into the visible beams directly!
The visible spot has around ±1.5cm deviation at 3m distance, please makes sure the correct curtain position.The visible
spot is used for rough calibration only
.
It’s not sufficient to get the precise position only by visible spots.
0-9 Number keys
Detection field
Redirection
Plus
Unlock
Minus
Output activation delay
Min. object size
Detection area activation
Mounting side
Output termination delay
FOG FILTER