25
Maintenance
• The purpose of the maintenance and adjustment schedule is to keep
the generator in the best operating condition.
• Inspect or service as scheduled in the table below.
maintenance
NOTICE
Use authorized parts or their equivalent. The use of replacement parts
which are not of equivalent quality may damage the generator.
WARNINg
Shut off the engine before performing any maintenance,
If the engine must be run, make sure the area is well
ventilated.
The exhaust contains poisonous carbon monoxide gas.
MAINTENANCE SCHEDULE
Regular Service Period (1)
ITEM
Perform at every indicated month or
operating hour interval, whichever
comes first.
Each Use
First Month
or 20hrs
Every 3
Months or
50hrs
Every 6
Months or
100hrs
Every Year
or 200hrs
Engine Oil
Check Level
Change
Air Cleaner
Check
Clean
Spark Plug
Check/Adjust
Spark Arrester
Clean
Valve Clearance
Check/Adjust
Fuel Tank and Filter
Clean
Fuel Line
Check
Every 2 years (Replace if Necessary)
(2)
(3)
(3)
NOTE:
1. Log hours of operation to determine proper maintenance.
2. Service more frequently when used in dusty areas.
3. These items should be serviced by an authorized dealer, unless the
owner has the proper tools and is mechanically proficient. See the
Shop Manual.