18
6. OPERATION
WARNING
• Never operate the engine in a closed area or it may cause
unconsciousness and death within a short time. Operate the
engine in a well ventilated area.
• Before starting the engine, do not connect any electric devices.
NOTICE
• The generator has been shipped without engine oil. Do not start
the engine till fill with the sufficient engine oil.
• Do not tilt the generator when adding engine oil. This could result
in overfilling and damage to the engine.
TIP:
The generator can be used with the rated output load at standard
atmospheric conditions.
Standard Atmospheric Conditions:
Ambient temperature 25°
Barometric pressure 100kPa
Relative humidity 30%
The output of the generator varies due to changes in temperature,
altitude (lower air pressure at higher altitude) and humidity.
The output of the generator is reduced when the temperature,
humidity, and the altitude are higher than standard atmospheric
conditions.
Addition
ally, the load must be reduced when using in a confined
area, as generator cooling is affected. We do not recommend using
the generator in a confined area, as adequate ventilation must be a
priority.
PREPARATION