15
Product Features
1. Automatic ON/OFF Pressure Switch
The compressor is equipped with an automatic on/off pressure switch.
The compressor will only run when the switch is in the “I”(ON) position.
Once the tank has reached the desired preset pressure (see Operation
Instructions), the pump will automatically shut off. While the switch is
in the “I”(ON) position, the pump will automatically turn back on once
the pressure in the tank drops below the minimum preset pressure. Do
not leave the compressor unattended while the power switch is in the
“I”(ON) position.
2. Regulator
The regulator allows you to select the amount of air pressure that is
output through the air hose into tools and accessories. Refer to the air
delivery requirements of your tools for the proper pressure settings.
3. Tank Pressure Gauge
The tank pressure gauge provides a reading of the air pressure inside
of the compressor tank.
4. Safety Valve
This compressor is equipped with a safely valve switch that will engage
when the pressure in the tank exceeds the maximum rated pressure.
DO NOT attempt to modify or remove safely valve.
5. Tank Drain Fitting
Water is produced whenever air is compressed. It is critical to drain
water from the air tank on this compressor frequently. If unit is used
only occasionally, tank should be drained after each use and prior to
the next use. To drain the tank, slowly open the tank drain fitting by
turning clockwise. Once all water has drained out, close the fitting
securely.
NOTE
: tank will not pressurize while fitting is open.
6. Safety Guard
The belt drive mechanism is protected by a metal guard. Do not
attempt to modify or remove this safety guard.
pROduct