64
!!
By responding to the
Enter Request:
message at the end of the main
configuration menu with "2" (Set Serial Port Configuration), you may
change the configuration of each serial port (i.e. baud rate, word size,
stop bits, parity, and XON/XOFF). Each port may be configured
individually. This allows Print Master to translate for devices using
different configurations.
Print Master will respond with a menu similar to:
Enter Port Number (5 to 6, 0=Exit), CR:
Type the desired port number followed by <ENTER>. For instance, if
you type "5" and <ENTER>, Print Master will respond with the current
status of Port 5 and a menu of the available options:
Port
Baud
Rate
Word
Size
Stop
Bits
Pariity
Xon/
Xoff
5
9600
8
1
None
Off
Exit/save......1 Set stop bits.....4
Set baud rate..2 Set parity........5
Set word size..3 Set Xon/Xoff......6
Enter request: