48
All configuration changes must be made through the master
configuration port. This master configuration port has access to all
options of the configuration mode. Please use the following
procedure to configure your Print Master 700C model:
1.
Connect a dumb terminal (or a PC running a terminal emulation
program) to the master configuration port which is Port 6 on the
706C, Port 8 on the 708C, Port 10 on the 710C. From the
factory, all serial ports are preset at 9600 baud rate, 8 word
size, 1 stop bit, no parity and XON/XOFF disabled.
NOTE: If you wish to use the BayTech TERM.EXE program to
configure your unit, refer to the instructions on the following
page.
2.
Make sure the keyboard of your computer is in the CAPS
LOCK position.
All ports on Print Master must be off-line (i.e, all LEDs must be
off except for the green power LED).
Send from the keyboard of the terminal or the PC
Control-T
(14 Hex) followed by capital C (43 Hex). These characters will
not appear on the CRT screen.
If any red LEDs on Print Master illuminate when
Control-T
and
C are sent or if Print Master gives no response (no menus
appear), this indicates that an incorrect character sequence
has been received. If so, wait for Print Master to time out
(LEDs will go out) and resend
Control-T
and capital C.
The Model 700C will respond with the main configuration menu. From
this point on, configuration of the 700C models will be menu driven.