2-29
Remote Annex 4000 Hardware Installation Guide
Chapter 2 Installing the Remote Annex 4000
If all requests fail, the Remote Annex 4000 will return to the ROM
monitor (if in Test mode) or continue the auto-initializing procedure
indefinately (if in normal mode).
BOOTP
For a successful
BOOTP
retrieval, a bootpd must be running on a host
on the same network as the Remote Annex 4000 and must have the
appropriate information in the bootptab file. The Remote Annex
4000’s BOOTP implementation adheres to rfc951, rfc1048, and
rfc1084. A sample bootptab file entry used to initialize the Remote
Annex 4000 named terminator looks like this:
In the previous example:
❑
sm is the subnet mask.
❑
gw is the load/dump gateway address.
❑
vm is the Vendor Magic Cookie.
❑
ht is host type (1=Ethernet).
❑
ha is the Remote Annex 4000’s hardware address (Ethernet
Address).
❑
ip is the Remote Annex 4000’s Internet Address.
remoteannexdefault:\
:sm=255.255.255.0:gw=132.245.22.66:\
:hn:vm=auto:to=-18000:
terminator:\
:ht=1:ha=00802d004879:ip=132.245.22.226:\
:tc=remoteannexdefault:
Summary of Contents for Remote Annex 4000
Page 1: ...Part No 166 024 151 Rev C March 1996 Hardware Installation Guide Remote Annex 4000 ...
Page 4: ...Remote Annex 4000 Hardware Installation Guide Revision Level History iv ...
Page 8: ...Remote Annex 4000 Hardware Installation Guide Contents viii ...
Page 10: ...Remote Annex 4000 Hardware Installation Guide Figures x ...
Page 12: ...Remote Annex 4000 Hardware Installation Guide Tables xii ...
Page 16: ...Remote Annex 4000 Hardware Installation Guide Preface xvi ...
Page 71: ...2 33 Remote Annex 4000 Hardware Installation Guide Chapter 2 Installing the Remote Annex 4000 ...
Page 72: ...Remote Annex 4000 Hardware Installation Guide Chapter 2 Installing the Remote Annex 4000 2 34 ...