Power Switch
The Power Switch disconnects AC power without disconnecting the
Remote Annex 4000 from the power source.
Power Select
Switch
The Power Select Switch selects the operational voltage range. The
Remote Annex 2000 automatically selects the operational voltage
range. The 110V position allows operation in the 90 to 130 VAC range;
the 220V position allows operation in the 180 to 260 VAC range.
AC Line Socket
The AC line socket supplies power to the Remote Annex 4000 through
the AC power cord. The AC power cord is plugged into this socket.
Physical Characteristics
The Remote Annex 4000 enclosure has the following characteristics:
❑
Dimensions:
Height: 3.5 in. (89 mm).
Width: 17.5 in. (445 mm).
Depth: 15.5 in. (394 mm).
❑
Weight:
16 lbs (7.3 kg).
❑
Power:
Internal supply.
90–130 VAC, 1.5A.
180–260 VAC, 0.75A.
47–63 Hz, 165W, 563 BTU/hr.
Summary of Contents for Remote Annex 4000
Page 1: ...Part No 166 024 151 Rev C March 1996 Hardware Installation Guide Remote Annex 4000 ...
Page 4: ...Remote Annex 4000 Hardware Installation Guide Revision Level History iv ...
Page 8: ...Remote Annex 4000 Hardware Installation Guide Contents viii ...
Page 10: ...Remote Annex 4000 Hardware Installation Guide Figures x ...
Page 12: ...Remote Annex 4000 Hardware Installation Guide Tables xii ...
Page 16: ...Remote Annex 4000 Hardware Installation Guide Preface xvi ...
Page 71: ...2 33 Remote Annex 4000 Hardware Installation Guide Chapter 2 Installing the Remote Annex 4000 ...
Page 72: ...Remote Annex 4000 Hardware Installation Guide Chapter 2 Installing the Remote Annex 4000 2 34 ...