background image

I

NSTALLATION

Issue 1.2

Page    7

M

ANAGER 

P

ORT

, C

ABLE AND 

C

ONNECTION

The manager port on the rear of the unit is presented as a standard RJ-45 connector.  A
3 metre cable terminated with an RJ-45 plug at each end, a 9 way and a 25 way "D"
type to RJ45 female connector are supplied to connect to a PC comm. port or terminal.

The manager terminal should be set up to operate with the following settings:
Baud Rate:

9600 bps 

Word Length:

8 bits

Parity:

None

Stop Bits:

One

RJ-45 Plug

25 Way D-type

To Marlin

To PC

Socket

4

3
5

7

8
2

20

1

8

2
3
5
6
7

or Adaptor

RXD output

CTS output

DCD output

TXD input
RTS input

DTR input

GND

7

2
1

5

6
3

4

9 Way D-type

Socket

V.24 Cable for Manager Terminal

S

ERIAL 

P

ORTS

, C

ABLES AND 

C

ONNECTIONS

S

TANDARD 

C

ONNECTION TO A 

DCE

To connect the Marlin to a digital leased circuit, use only the cable(s) supplied with the
Marlin.

Summary of Contents for Marlin

Page 1: ...MARLIN INSTALLATION GUIDE Issue 1 2 ...

Page 2: ...able form without the prior written permission of Bay Networks Inc The information contained in this manual is believed to be accurate However no responsibility whatsoever is assumed by Bay Networks Inc for its use nor for any infringements of patents or other rights of third parties resulting from its use All trade marks are acknowledged 1997 Bay Networks ...

Page 3: ...er Bay Networks software products are licensed for use under the terms of the applicable Bay Networks Inc Software License Agreement that accompanies such software and upon payment by the end user of the applicable license fees for such software 2 Restrictions on use reservation of rights The Software and user manuals are protected under copyright laws Bay Networks and or its licensors retain all ...

Page 4: ... b that the Software will operate in the hardware or software combinations that the Licensee may select c that the operation of the Software will be uninterrupted or error free or d that all defects in the operation of the Software will be corrected Bay Networks is not obligated to remedy any Software defect which cannot be reproduced with the latest Software release These warranties do not apply ...

Page 5: ...terminated however all of the restrictions with respect to Bay Networks copyright in the Software and user manuals will cease being effective at the date of expiration of the Bay Networks copyright those restrictions relating to use and disclosure of Bay Networks confidential information shall continue in effect Licensee may terminate this license at any time The license will automatically termina...

Page 6: ... O Box 58185 Santa Clara California 95052 8185 LICENSEE ACKNOWLEDGES THAT LICENSEE HAS READ THIS AGREEMENT UNDERSTANDS IT AND AGREES TO BE BOUND BY ITS TERMS AND CONDITIONS LICENSEE FURTHER AGREES THAT THIS AGREEMENT IS THE ENTIRE AND EXCLUSIVE AGREEMENT BETWEEN BAY NETWORKS AND LICENSEE WHICH SUPERSEDES ALL PRIOR ORAL AND WRITTEN AGREEMENTS AND COMMUNICATIONS BETWEEN THE PARTIES PERTAINING TO THE...

Page 7: ... selected to provide continued conformance with the requirements of 2 3 for SELV circuits and with the requirements of clause 6 for TNV circuits after making connections between equipment EMC This device complies with requirements of EMC with EN55022 and EN5882 1 approvals NETWORK CONNECTION This device has been approved by BABT for connection to ISDN Services under approval number AA604444 This d...

Page 8: ...uant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipm...

Page 9: ...y be useful to save the packaging in which the unit was delivered This will help to protect the unit should it be required to move it in the future to a different location ENVIRONMENTAL REQUIREMENTS Before commencing the installation process ensure that the environment into which it is being installed is appropriate Table 1 below defines the operating environment which the Marlin will operate with...

Page 10: ...ower Consumption 18 Watts Operating Temperature 5 to 45 C Humidity 5 to 95 non condensing Table 1 Operating Environment PHYSICAL DESCRIPTION The Marlin is a compact chassis containing a high performance RISC microprocessor based communications engine with integral power supply which will support a number of networking applications The Marlin Platform ...

Page 11: ...r Vn m c 1995 Scorpion Logic Ltd Passed 4Mb Passed 4Mb appears when test complete n m will be the Loader version number installed and Copyright notice Dynamic memory test Marlin Bootstrap Loader Vn m At this stage the Marlin will start loading its operational software The display will vary depending on whether the router or bridge software is installed The router software once initialised will cau...

Page 12: ...s supply The mains plug is the primary disconnect device for the unit and you must ensure that the unit is installed near to a socket outlet and that the outlet is accessible The mains cable supplied with the unit is fitted with a moulded plug for connection to the standard socket outlet The use of adapters is not recommended and may invalidate the product s approval The wires in the supply cord a...

Page 13: ...manager terminal should be set up to operate with the following settings Baud Rate 9600 bps Word Length 8 bits Parity None Stop Bits One RJ 45 Plug 25 Way D type To Marlin To PC Socket 4 3 5 7 8 2 20 1 8 2 3 5 6 7 or Adaptor RXD output CTS output DCD output TXD input RTS input DTR input GND 7 2 1 5 6 3 4 9 Way D type Socket V 24 Cable for Manager Terminal SERIAL PORTS CABLES AND CONNECTIONS STANDA...

Page 14: ...ere are certain rules which must be followed when installing new transceivers onto a 10Base5 Ethernet cable References should be made to the transceiver manufacturers instructions for full details A standard Ethernet Transceiver Drop Cable should be connected between the LAN AUI port on the Marlin and the transceiver 15 way Pin Nbr Signal Function Signal Name 1 Control In Circuit Shield CI S 2 Con...

Page 15: ... within the limits of SELV Ethernet 10BaseT attachment to LAN SELV AUI 10Base5 attachment to LAN SELV J701 Expansion Slot connector SELV J300 GCI daughter card connector SELV Interconnection circuits shall be selected to provide continued conformance with the requirements of EN 609050 1992 A3 1995 clause 2 3 for SELV circuits and with the requirements of clause 6 for TNV circuits after connections...

Page 16: ...ssue 1 2 Page 10 APPENDIX The pin out of these cables is provided for information only WAN CABLE CAB MWAN V11 Network DCE End 15 way D type plug with retainer screws 2 T 9 T 3 C 10 C 4 R 11 R 5 I 12 I 6 S 13 S 8 GND ...

Page 17: ... 2 Page 11 WAN CABLE CAB MWAN V24 Network DCE End 25 way D type plug with retainer screws 1 SCREEN 2 TXD 3 RXD 4 RTS 5 CTS 6 R DSR 7 R GND 8 DCD 15 TXC 17 RXC 20 DTR R DCE connector has 5K6 resistor between pin 6 and pin 7 ...

Page 18: ... WAN CABLE CAB MWAN V35 Network DCE End 34 way D type plug with retainer screws A SCRN T RXD R RXD C RTS D CTS H DTR B R GND E R DSR S TXD P TXD AA TXC Y TXC X RXC V RXC F DCD R DCE connector has 5K6 resistor between pin E and pin B ...

Reviews: