Installing and Maintaining the HRPSU
1-4
114312 Rev. C
For network devices that use 16-pin cables, you must install a connector adapter to
attach the cable to the HRPSU.
Depending on the particular network device type, the HRPSU attaches to network
devices using 16-pin cables or 24-pin cables. For example:
•
The ASN uses a single 24-pin cable.
•
BayStack and Distributed 5000 device’s use a single 16-pin cable.
•
The 28000 family devices use two 16-pin cables.
Standoffs are provided for 24-pin cable connections, and for attaching 16-pin
adapters for those network devices using 16-pin cables. Once all cabling is
complete and the AC power is turned on, the HRPSU is enabled; signals
automatically sent to the network device inform it of the presence of the HRPSU
-- no other setup is required.
The HRPSU power switch turns off all power to the unit. The AC power cord
plugs into a wall outlet. This allows the network device to have an AC power
source separate from the HRPSU. The HRPSU requires a dedicated 15-A branch
circuit for 120-V AC power service.
North American and Japanese users need to use the Bay Networks 15-A power
cords for their countries (Order Nos. AA0018020 and AA0020001, respectively).
All other countries use the standard Bay Networks 10-A power cord, at 240 V AC,
for their particular country.
Preparing for Installation
Before you install the HRPSU:
•
Check your shipment.
-
Verify that the items you received match the packing list attached to
the shipping container.
-
Inspect all items for damage.
If any parts are missing or damaged, contact the Bay Networks Technical
Response Center for assistance.
•
Make sure that your site meets the electrical requirements described in
Appendix A.