7221369.01 (1-03/15)
38
INST
ALLER Section
(en)
CONFIGURATION
P40
5700
Not used (Do NOT change this parameter)
-
---
---
---
P41
5710
Zone 1 heating circuit (1=enabled)
-
1
0
1
P42
5715
Zone 2 heating circuit (1=enabled)
-
0
0
1
P43
5730
DHW sensor (1=Tank sensor, 2=Thermostat, 3=instantaneous sensor)
1
1
3
P44
5890
Not used (Do NOT change this parameter)
-
33
0
43
P45
5931
*BX2 sensor input (first auxiliary sensor – section 11)
-
0
0
19
P46
5932
*BX3 sensor input (second auxiliary sensor – section 11)
-
0
0
19
P47
5977
*Input H5 (multifunction input – 18=Room thermostat)
-
18
0
32
P48
6020
*Configuration of accessory Expansion Unit
-
0
0
7
P49
6024
Input EX21 module 1 (configuration of HC Safety Thermostat)
-
0
0
1
P50
6046
Input H2 module 1 (multifunction input)
-
0
0
58
P51 6097
Sensor type collector (1= NTC, 2= Pt 1000)
-
2
1
2
P52 6110
Building time constant (depending on the insulations of the building)
h
15
0
50
P53 6220
Software version
-
---
0
99
P54 6600
LPB device address (BUS connection)
-
1
16
P55 6601
LPB segment address (BUS connection)
-
0
14
P56 6640
Clock time source
-
0
3
MAINTENANCE
P57 7045
Time after maintenance
month
xxx
0
240
P58 6704
View/Hide secondary fault internal code (0=no)
-
1
0
1
BURNER CONTROL
P59 9512
Required ignition speed
rpm
xxx
0
8000
P60 9524
Required minimum operating speed (low speed)
rpm
xxx
0
8000
P61 9529
Required maximum operating speed (high speed)
rpm
xxx
0
8000
BOILER CONTROL PANEL PARAMETERS
P62
-
Unit of measurement (1=bar, °C – 2=PSI, °F)
-
1
1
2
P63
-
Control panel operation: (1=central, 0=local)
-
1
0
1
P64
-
Software version
-
xx
0
999
*
see “Accessories not included in supply”
xx
: the value depends on the software version
xxx
: the value depends on the type of boiler
(a)
: parameters read on the front boiler panel (fixed control panel)
(b)
: parameters read on the Remote Control
Summary of Contents for luna duo-tec MP+ 1.35
Page 90: ...7221369 01 1 03 15 90 S E C T I O N A 20...
Page 95: ...95 S E C T I O N C 7221369 01 1 03 15 G 3 4 G 1 G 1 95 123 100 100 CR_0774 75 5 51 5 43 22 O...
Page 98: ...7221369 01 1 03 15 98 S E C T I O N F AGU 2 550 CR_0349 CR_0349 AVS 75...
Page 99: ...99 S E C T I O N F 7221369 01 1 03 15 CG_2482 Tmax 50 C...