23
10.0
Annual Servicing – Page 23
10.5 Cleaning the Electrode
(Fig. 42 & 43)
1. Check for any signs of cracking or other damage to the
ceramic.
2. Clean the electrode wire if necessary.
3. Upon re-assembly check the spark gap is 2.5-4.0mm.
10.6 Completing Servicing
1. Clean any dirt and debris from the combustion box and
fireplace recess.
2. Reassemble the fire in reverse order of dismantling and
refit into the opening.
3. Recommission the fire.