Electrical – Page 11
4.1 Electrical Supply & Connection
1. All the fire controls are operated from the control panel
on the upper right hand side of the fire trim.
2. This appliance is supplied with a transformer and
connecting lead which provides the appliance with both
24V and 1 2V electrical power for the controls and
illumination.
3. The transformer plugs directly into a standard 13 amp
supply socket.
4.
A cable extension kit is available (Part N
o
245553)
should a longer length be required between the
transformer and the fire. The extended lead is 4m long
and should be installed in the same manner as the
standard length lead.
5. The electrical supply cable can be routed through the
fireplace opening and via the fire back panel. Where the
cable passes through brickwork or similar it should be
suitably protected and sealed. The grommet should be
removed from the fire rear panel and cut in order to
accommodate the cable and replaced.
6. Ensure the transformer is easily accessible to the user
after installation.