6
2.0
Technical Data – Page 6
Kingston 2 Deluxe
Wentworth Deluxe
Category of Appliance
2H
Category of Appliance
2H
The fire is set for Gas Type G20 at 20mbar.
The fire is set for Gas Type G20 at 20mbar.
Heat Input
(net)
KW
Btu/h
High
6.16
21,018
Min
3.0
10,236
Heat Input
(net)
KW
Btu/h
High
6.16
21,018
Min
3.0
10,236
Heat Output
KW
Btu/h
High
4.0
13,650
Heat Output
KW
Btu/h
High
4.0
13,650
Inlet Setting Pressure
mbar
in wg
Cold
20 ± 1.0
8 ± 0.4
Inlet Setting Pressure
mbar
in wg
Cold
20 ± 1.0
8 ± 0.4
Gas Connection
8mm OD tube, rigid or semi rigid
and 8mm compression fitting at
appliance inlet
Gas Connection
8mm OD tube, rigid or semi
rigid and 8mm compression
fitting at appliance inlet
Controls &Safety
system
Fully automatic gas valve with
direct burner ignition, flame
failure device and direct acting
oxygen depletion system.
Controls &Safety
system
Fully automatic gas valve
with direct burner ignition,
flame failure device and
direct acting oxygen
depletion system.
Gas Rate
(after 10 mins)
0.65 m
3
/h
(23.0 ft
3
/h)
Gas Rate
(after 10 mins)
0.65 m
3
/h
(23.0 ft
3
/h)
Lifting Weight
34.3 kg (75.5 Ibs)
Lifting Weight
21.7 kg (47.74 Ibs)
Injector
Cat 127/440
Injector
Cat 127/440
Trim
Height
655mm
Trim
Height
601mm
Dimensions
Width
560mm
Dimensions
Width
512mm
Depth
110mm
Depth
110mm
(from the wall)
(from the wall)
Electricity Supply
230V transformer supplying fire
with 24V/12V supply.
Electricity Supply
230V transformer supplying