21
10.0
Annual Servicing – Page 21
10.2 Preparation
1. For reasons of safety and economy it is important to
service the fire annually.
WARNING: Isolate the gas and any electrical supply to
the appliance before servicing.
2. Remove the controls access door and fender assembly
(Fig. 33).
3. Remove the trim (Fig. 33).
4. Carefully remove all the loose coals, front and rear coal
mouldings and the side cheeks (Fig. 34).
5. Undo the disconnecting union on the gas supply (Fig.
35).
6. Undo the three screws retaining the burner chassis to
the combustion box sides and combustion box base.
Withdraw the burner chassis from the fire (Fig. 36). It will
be necessary to unplug the switch at the top right hand
side of the fire and also the transformer plug from the
control box front.
7. Slacken the cable tensioning nut and remove the
solderless nipples from the cables (Fig. 37).
8. Where applicable, remove the grommet from the gas
and/or electrical supplies if they are routed through the fire
rear panel (Fig. 36).
9. Pull the fire forwards out of the opening, disengage the
cables from the eyebolts and lift the fire away from the
hearth. If the fire is secured to the fireplace using screws,
remove in order to release the fire from the fireplace.