32 Model Supplement
14
14
32 Model Supplement
14.1 32 Model Supplement
Heat Input Qn Hs
(Gross)
Max Min
32 model kW 35.52 6.99
Heat Output Pn
(Non-Condensing)
Max Min
32 model kW 32 6.1
Appliance Category
CAT I
2H
Heat Output Pnc
(Condensing)
Max Min
32 model kW 33.9 6.6
Appliance Type
C
13
C
33
C
53
Gas Nozzle Injector
32 model mm Ø 6.0
Power Consumption
32 model W 90
Dynamic (nominal) Inlet Pressure
(Natural Gas - G20)
mbar 20
with a CV of 37.78 MJ/m
3
Max Gas Rate
(Natural Gas - G20)
(After 10 mins)
32 model m
3
/h 3.38
NATURAL GAS ONLY !
Weights
(32 model)
Packaged Boiler Carton 43.2kg
Installation Lift Weight 37.5kg
Outercase Dimensions
Casing Height - 763mm
Overall Height Inc Flue Elbow - 923mm
Casing Width - 450mm
Casing Depth - 345mm
Expansion Vessel
- (For Central Heating
only. Integral with appliance)
bar
Min Pre-charge Pressure 1.0
litre
Max Capacity of
CH System 155
Primary Water Content
of Boiler (unpressurised) 2.8
150mm* Min
763mm
450mm
175 mm Min (300mm
Min if using 80/125mm
flueing system)
5mm Min
5mm Min
*
This is MINIMUM
recommended dimension.
Greater clearance will aid
installation and maintenance.
5mm Min In
Operation
450mm Min
345mm
For Servicing
Purposes &
Operating the
Controls
At least
1.5°