![Baxi EcoBlue 12 System ErP Installation And Service Manual Download Page 15](http://html1.mh-extra.com/html/baxi/ecoblue-12-system-erp/ecoblue-12-system-erp_installation-and-service-manual_2711775015.webp)
7219708 - 01 (04/15)
EcoBlue System
15
Technical Specifications
3
0
200
400
600
800
1000
1200
0.5
1
1.5
2
2.5
3
3.5
4
Metre (wg)
Flow Rate (l/h)
Pump - Available Head
0
5
5.5
6
4.5
Pump
Available Head See graph below
Dynamic (nominal) Inlet Pressure
(Natural Gas - G20)
mbar 20
with a CV of 37.78 MJ/m
3
Max Gas Rate
(Natural Gas - G20)
(After 10 mins)
12 model m
3
/h 1.27
15 model m
3
/h 1.58
18 model m
3
/h 1.90
24 model m
3
/h 2.54
28 model m
3
/h 2.96
NATURAL GAS ONLY !
SAP 2009 Annual Efficiency is
12 model - 89.2%
15,18,24,28,32 models - 89.1%
This value is used in the UK Government’s
Standard Assessment Procedure (SAP) for energy
rating of dwellings. The test data from which it has
been calculated has been certified by 0085.
Product Characteristics Database
(SEDBUK)
NOTE:
All data in this section are nominal
values and subject to normal production
tolerances.
3.1
Technical Data (cont)
See Section 14.1 ‘32 Model Supplement’
for data specific to the 32 model