![Baxi Bermuda SP3 Installation And Servicing Manual Download Page 24](http://html.mh-extra.com/html/baxi/bermuda-sp3/bermuda-sp3_installation-and-servicing-manual_2711686024.webp)
Supplied By www.heating spares.co Tel. 0161 620 6677
Ensuring that the glass frame is cold, disengage the
retaining clamps and lift the frame away.
Remove the coal bed by carefully
lifting away from the locating pins and
place to one side.
Cleaning the Pilot / A.S.D. Assembly
WARNING:
The A.S.D. pilot assembly must not be
adjusted in any way.
The A.S.D. must not be altered so that it will not
operate or be bypassed in any way.
Ensure that the pilot burner aeration hole is free from
lint, debris etc.
If necessary clean the electrode and target, and check
that the spark gap is 2.5 - 4.0mm.
The thermocouple cannot be changed as an individual
component. The complete assembly must be replaced
in the event of one or other component failure(s).
Only use a Genuine Baxi Spare Part.
24