asbestos or asbestos related products.
*
When converted using kit 0595241
Page 5
4. GENERAL INSTALLATION REQUIREMENTS
4.1
The installation must be in accordance with these instructions.
For the user's protection, in the United Kingdom it is the law that all gas appliances are installed by competent
persons in accordance with the current edition of the Gas Safety (Installation and Use) Regulations. Failure to
install the appliance correctly could lead to prosecution. The Council for the Registration of Gas Installers
(CORGI) requires its members to work to recognised standards.
In the United Kingdom the installation must also be in accordance with:
All the relevant parts of local regulations.
All relevant codes of practice.
The relevant parts of the current editions of the following British Standards:-
In England and Wales, the current edition of the Building Regulations issued by the Department of the
Environment and the Welsh Office. In Scotland the current edition of the Building Standards (Scotland)
Regulations issued by the Scottish Executive. In Northern Ireland, the current edition of the Building
Regulations (Northern Ireland) issued by the Department of the Environment for Northern Ireland. In the
Republic of Ireland the installation must also conform with the relevant parts of:
The current editions of:-
Gas
Natural (G20)
Propane (G31)
*
Inlet Pressure
20mbar
37mbar
Input - Max. (Gross)
6.85kW (23,372 Btu/h)
6.7kW (22,860 Btu/h)
Input - Min. (Gross)
2.3kW (7,846 Btu/h)
4.0kW (13,650 Btu/h)
Inlet Test Pressure (Cold)
20.0 ± 1.0mbar (8.0 ± 0.4in
w.g.)
37.0 ± 1.0 mbar (14.85 ±
0.4in w.g.)
Gas Connection
8mm pipe
8mm pipe
Burner Injector
SU - 078
Stereomatic size 132
Pilot & Atmosphere Sensing
Device
SU - 028
SU - 020
Ignition
Integral Piezo Spark
Integral Piezo Spark
Aeration
See
section 11.1
Non-adjustable
BS 1251 BS
4543 Part 2
BS 5440 Part 1
BS 5440 Part 2
BS 5871 Part 3
BS 6461 Part 1
BS 6891
BS 8303
Page 4 of 25
20/08/2012
http://www.partsarena.com/baxi/System/DATA/Dx/DS1/installation/2642/I39-2642/I...