PRODUCT SAFETY

•

Please follow these instructions as you install the equipment and keep them for

future use. If you have any problems, contact Baxall Limited.

•

Installation is only to be carried out by competent, qualified and experienced

personnel. Wire in accordance with the country of installation’s National Wiring

regulations. Failure to do so can result in death or injury by electric shock.

•

The equipment supplied with this manual is designed for use in a general purpose

CCTV installation and has no other function.

•

Before undertaking any installation or maintenance, the mains supply must be

disconnected.

•

This product should only be used with the su12V DC power supply (Baxall

Reference PSU11 or PSU14).

•

Do not exceed the voltage and temperature limits given in the specifications.

•

Only  use  your  DVS  Series  Desktop  Video  Switcher  in  a  clean,  dry,  dust-free

environment.

•

Before cleaning this equipment, isolate the unit. Use only a dry, lint-free cloth. Do

not use cleaning fluids or solvents.

ELECTROMAGNETIC COMPATIBILITY (EMC)

CAUTION

•

This  product  is  intended  for  use  in  general  purpose  CCTV  applications  in  a

residential,  commercial  or  light  industrial  EMC  environment.  Refer  to  Baxall

Limited before using the product is medical and/or intrinsically safe applications

or in an industrial EMC environment.

•

This product must be installed in accordance with good installation practice for

EMC to enable the product to function as intended and to prevent EMC problems.

MANUFACTURER’S DECLARATION OF CONFORMANCE

A “Declaration of Conformity” in accordance with the following EU standards has been

made and is on file at Baxall Limited, Stockport, SK6 2S, England.
The manufacturer declares that the product supplied with this document is compliant with

the provisions of the EMC Directive 89/336 EEC, the Low Voltage Directive LVD 73/23

EEC, the CE Marking Directive 93/68 EEC and all associated amendments.

UNPACKING

Keep your packaging for use if the product is to be stored for an extended period or needs

to be returned for any reason. The packaging should contain:
•

A DVS Series Desktop Video Switcher (DVS14, DVS18, DVS24A, or DVS28A)

•

A mains-socket mo12V DC power supply (class 2)

•

15-way alarm connector plug and cover (with DVS24A and DVS28A only)

•

These instructions

Check the product code on the serial number label. If you have an incorrect item or it is

damaged then inform the suppliers and carriers immediately. If this is the case then do not

attempt to use the equipment.

Summary of Contents for DVS14

Page 1: ...DVS Series Desktop Video Switchers Installation and Operating Manual Please read these instructions before installing your equipment...

Page 2: ...ion and Operating Manual 2 IMPORTANT The first few pages of these instructions contain important information on safety and product conformity Please read and ensure that you understand this informatio...

Page 3: ...eclaration of Conformance 4 Unpacking 4 Overview 5 Rear Panel Connections 7 Connecting the Switcher 8 Alarm I O Connector 9 DVS14 and DVS18 Operation 10 DVS24A and DVS28A Operation 11 The On Screen Me...

Page 4: ...esidential commercial or light industrial EMC environment Refer to Baxall Limited before using the product is medical and or intrinsically safe applications or in an industrial EMC environment This pr...

Page 5: ...efinable camera titles Aside from these common features DVS Series switchers fall into two groups those with alarm functionality and those without DVS14 and DVS18 The DVS14 can be connected to four ca...

Page 6: ...uired Sequences can also be run simultaneously on both monitors Both the DVS24A and DVS28Aunits have alarm functionality The alarm inputs are designed so that when an alarm is triggered the main monit...

Page 7: ...s Video Output Power Connector Power supply cable strain relief point DVS18 Video Inputs Video Outputs Alarm I O Connector Power Connector Power supply cable strain relief point DVS24A Video Inputs Vi...

Page 8: ...nputs DVS24A or DVS28A connect the Alarms I O Connector 5 Connect the jack plug from the 12V DC power supply into the jack socket marked 12V DC Use the power supply cable strain relief point to preven...

Page 9: ...GROUND Pin 1 Figure 5 Alarm Input Connections Alarm Outputs An internal relay is provided so that the DVS can be connected to other equipment The behaviour of this relay can be programmed using the m...

Page 10: ...sing the button for a video source that doesn t have a camera connected to it will display a NO VIDEO message until another camera is selected Auto Mode To operate the unit in Auto mode press the Auto...

Page 11: ...n t have a camera connected to it will display a NO VIDEO message until another camera is selected The unit can also be used to manually select and display cameras on the spot monitor To do this hold...

Page 12: ...uto mode press any of the input selection buttons Note The DVS24A and DVS28A are fitted with alarm inputs The operation of the switchers when in alarm condition depends largely on the settings in the...

Page 13: ...buttons The and buttons are then used to change the selected parameter for that menu item A menu item with no parameters indicates that a sub menu exists To reveal the sub menu highlight the menu item...

Page 14: ...is also shown so that the source of the images is easily identifiable For more details see page 15 Dwell Select this option to enter the Dwell sub menu This sub menu is used to specify the dwell time...

Page 15: ...be selected 2 Using the and buttons highlight the character in the camera title that is to be changed 3 Press the OK button The Letter Selection screen is displayed 4 Using the and buttons navigate th...

Page 16: ...a input and each of these fields indicates a dwell time in seconds To alter the dwell time of an individual camera input use the and buttons to select the required camera input and use the and buttons...

Page 17: ...put is no longer current When using this option there is no need for an alarm input to be acknowledged and cleared by an operator Ack Acknowledge An alarm input must be cleared by pressing the button...

Page 18: ...ore the alarm was activated OUTPUT This item is used to specify how the relay contact a set of three pins in the Alarms I O Connector that controls the alarm output works when an alarm input is trigge...

Page 19: ...ad woodscrews 2 Fit screw A leaving it protruding from the surface by approximately 6 5mm 3 Locate the keyhole shaped slot on the underside of the DVS unit over the head of the screw Slide the DVS unt...

Page 20: ...m Dwell time is individually adjustable between 1 and 60 seconds on main monitor and globally adjustable between 5 and 60 seconds on second monitor 12 character camera title for each input individuall...

Page 21: ...1 75 5mm 75 5mm 95mm Max Hole Size 3 8mm Max Hole Size 3 8mm Max Hole Size 3 8mm ORIGINAL SCALE 1 1 It is imperative that the dimensions on the supplied template are checked to ensure that the diagram...

Page 22: ...DVS Series Installation and Operating Manual 22...

Page 23: ...Installation and Operating Manual DVS Series 23...

Page 24: ...HB DVS 3 Baxall Limited Stockport England Visit our Web site http www baxall com Baxall Limited reserve the right to make changes to the product and specification of the product without prior notice t...

Reviews: