Installation
Mono Power Unit BUM 62 T
45
Baumüller Nürnberg GmbH
5.99009.03
Plug-in terminal X99 AB
Screw connections for cable with wire crimp.
1. Position
2. Voltage range (r.m.s. value)
3. Current range (r.m.s. value)
4. Cross-section of the conductor
5. This message only refers to the BUM 62 T, and not to the controller!
(see also ”Messages via relay contacts” on page 61 )
Termina
l
Pos.
1)
Description
U
range
2)
I
range
3)
A
4)
1
Message
"External ready for operation"
5)
Open contacts.
Supply part not ready
Closed contacts.
Supply part ready
24 V
0.5 A
max.
2.5 mm
2
2
3
Message
"Early warning"
5)
Closed contacts.
Supply part – no early warning
Open contacts.
Supply part – early warning
4
+Reset
5
isolated optocoupler input to
reset error messages.
PHASE ERR, POWER ERR, and BRAKE
OVERL.
24 V
-
M Reset
6
Reference to input +Reset
0 V
-
Summary of Contents for BUM 62 T
Page 1: ...E 5 99009 03 Manual BUM 62 T Mono Power Unit ...
Page 6: ...6 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 10: ...Safety notes 10 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 18: ...Transportation Unpacking 18 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 22: ...Assembly 22 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 48: ...Installation 48 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 62: ...Commissioning 62 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 66: ...Maintenance 66 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Page 73: ......