Bluetti ACB300 User Manual Download Page 1

AC300 

Portable Power Station

Please read this manual before use and follow its guidance. Keep this manual for future reference.

Summary of Contents for ACB300

Page 1: ...AC300 Portable Power Station Please read this manual before use and follow its guidance Keep this manual for future reference ...

Page 2: ...read this manual before use and follow its guidance Keep this manual for future reference W W W W AC Load DC Load PV Homepage Settings Data Grid Alarm 12 0 0 0 20 120 00 0 0 0 0 20 2021 01 10 10 54 30 AC OFF AC OFF DC OFF ...

Page 3: ...URES OF AC300 11 06 STARTUP POWER OFF 11 07 USER INTERFACE 12 08 HOW TO RECHARGE AC300 B300 INPUT 19 09 DISCHARGE OUTPUT 25 10 UPS 28 11 SPLIT PHASE FUNCTION 32 12 TECHNICAL SPECIFICATION 36 13 STORAGE AND MAINTENANCE 38 14 TROUBLESHOOTING 38 15 FAQ Frequently Asked Questions 43 16 DECLARATION 44 17 FCC WARNING 45 ...

Page 4: ...t one B300 connected and supports up to four B300 battery packs connected This product integrates a solar charge controller AC charge controller AC inverter lithium battery and battery management system into one It converts clean and environmentally friendly solar energy and grid electricity into clean electricity and sends it to all of your connected loads Main Panel BLUETTI Sub Panel AC300 grid ...

Page 5: ...ther component of the equipment by anyone other than authorized personnel There are no enduser serviceable components DO NOT operate in wet conditions If the equipment becomes wet please let the unit dry completely before using Please ensure proper ventilation while in use and do not obstruct fan openings Inadequate ventilation may cause permanent damage to the equipment DO NOT move the unit while...

Page 6: ...rews Live operation is strictly prohibited during installation Paint scratches during equipment transportation and installation must be repaired in a timely manner Long term scratches are strictly prohibited and may cause damage Before operation the equipment should be secured onto a floor or other stable objects such as walls or possibly mounting brackets if needed It is prohibited to clean any e...

Page 7: ...les into the equipment Drilling will alter and damage the electromagnetic shielding performance of the equipment internal components and cables The risk of metal shavings entering the device can cause short circuits on the circuit board Wear goggles and protective gloves when drilling holes The equipment should be shielded and protected during the drilling process to prevent debris from falling in...

Page 8: ...Charging Cable For solar car lead acid battery charging 1 4 Car Charging Cable Charging AC300 B300 with cable No3 1 5 AC300 POWER STATION Please read this manual before use and follow its guidance Keep this manual for future reference User Manual 1 6 AC300 POWER STATION Please read this manual before use and follow its guidance Keep this manual for future reference Warranty Card 1 7 AC300 POWER ST...

Page 9: ...id battery 10 PV Drop Down Module D300S Connect to rigid panels 11 12V 30A XT60 to Aviation Plug For 30A DC Output 12 XT60 to SPC45 To support DC power supply for RV 13 100W USB C to USB C To charge electronics with USB C port 14 AC Charging Cable for Split Phase Charging two AC300 connected in split phase mode via wall outlet 15 Sub Panel Integrate the power station to your home circuit as backup...

Page 10: ...ETTI in the App Store for iOS devices or Google Play for Android devices to download the BLUETTI App to remotely control your AC300 B300 The AC300 B300 system can be controlled via either Bluetooth or Wi Fi In order to access the AC300 B300 please launch the BLUETTI App once downloaded and installed and tap the LOGIN icon to register your BLUETTI account Fill with your related information to conti...

Page 11: ...account Step 2 Connect AC300 with B300 Scan the unique QR code on AC300 to add the unit on the available device list on the App and fill it with the password of your 2 4GWi Fi network to activate the communication function of AC300 for data syncing For Bluetooth Connecting tap CONNECT at the homepage to connect AC300 B300 with your phone via Bluetooth select the SN number of your devices ...

Page 12: ... be viewed after the unit is connected with App successfully Tap gear icon to customize the current working mode and parameters of your AC300 under Settings The BLUETTI App supports a Firmware Update function which allows access to the latest software upgrades for continued features improvements and fixes ...

Page 13: ... BLUETTI App Also if BLUETTI APP fails to connect to the Internet Tap Settings on the mainpage of your phone and scroll down until the BLUETTI App shows up IOS Tap Settings on mainpage of your phone tap Application Management and select BLUETTI Android Tap the BLUETTI icon and verify that Wireless and Data permissions are enabled ...

Page 14: ... AC Output Port 20A MAX AC Output Port 30A MAX Wireless Charging Pad Power Button USB C PD3 0 protocol supported Battery connection port AC Input Port DC1 DC2 Input Port Communication Interface 06 STARTUP POWER OFF Connect AC300 with B300 Please follow the steps on B300 User Manual Power On AC300 Long press the power button for 1 second The power ...

Page 15: ... automatically from Power Off status when either grid charging and or PV charging is applied to the unit User can also power ON OFF of the system by turning ON OFF B300 AC300 B300 will turn off in 4 hours under a No Input and Output b AC and DC switch at OFF state 07 USER INTERFACE 7 1 Main Interface Tip The LCD resistive touchscreen recommended to press lightly with the edge of your fingernail un...

Page 16: ...t be set to 220 240V AC output Users can tap the screen to set the parameters as needed Output frequency and voltage can only be tweaked when the AC is OFF tap the AC icon at homepage to turn off AC output The list of standard output voltage and frequency in 5 regions or countries JP Output 100V 50 or 60Hz US Output 120V 60Hz AU Output 240V 50Hz EU UK Output 230V 50Hz 7 2 2 DC Input Source DC Inpu...

Page 17: ...C2 Input Source Cable No 3 7 2 3 Language Setting ECO Mode Press English or Japanese icon to set as the system language display of your AC300 ECO The power saving mode of the unit to turn off the AC output to conserve energy if the AC load is less than 30W over 4 hours ...

Page 18: ...commended for areas in stable power supply Customized UPS Mode Customized the parameters for a better user experience For more details on each UPS Mode setting please read Chapter 10 UPS 7 2 6 Max Grid Input Current Please check the specification of your grid sockets connections wires etc to determine the maximum allowable current that can be drawn by the AC300 BLUETTI is not liable for any damage...

Page 19: ...d time setting in order to set the date and time as applicable to your local time zone Tap to Enable Disable touch sound You may change the Backlight Brightness of the LCD by using the slider on the screen 7 2 8 Bluetooth Wi Fi Connection The Bluetooth and Wi Fi connection can be turned ON or OFF by tapping the ON and OFF icon for either function User cannot connect AC300 B300 to BLUETTI App when ...

Page 20: ...d Alarm Fault History 7 3 1 Product Info When you select the Product Info button you can view the product model serial number SN control software version monitoring software version BMS monitoring software version and display software version The Serial Number SN can also be used to pair to BLUETTI APP manually ...

Page 21: ...e homepage 7 3 3 Battery Information By tapping the Battery Information button user can view the live information of the status of the B300 battery pack This section can also be accessed directly from the shortcut icon on the homepage 7 3 4 Alarm History Tap the Alarm History button user can view all the alarm information generated by the machine User can turn to the Chapter 14 Troubleshooting to ...

Page 22: ...t 1 CP2 EV Charging Station Wind Turbine Generator Solar panels T500 adapter Car Lead acid Battery By using BLUETTI Wind Turbines an ultra connect highly efficient wind charger lets you harness the wind to rapidly recharge the AC300 B300 Now you can also get dash charging via the EV charging stations all over the US soil AC300 B300 supports AC generator solar additional adapter car lead acid batte...

Page 23: ... Wall Outlet Main Panel Sub Panel Charging via wall outlet Charging via BLUETTI Sub Panel 8 1 2 Charging Method 2 From Generator gasoline propane or diesel Connect the AC300 from CP1 via the generator charging cable sold separately to the AC output of the generator The charging process will automatically stop when it reaches 100 The required output power of your generator has to exceed the Max inp...

Page 24: ...inputs Each individual input supports up to 12A and the charging voltage should be between 12 150V The AC300 B300 can achieve a combined maximum of 2400W of total solar input a User can connect solar panels in series Figure 1 b Connect the MC4 port of solar panels to the MC4 Aviation cable Figure2 3 c Plug the Aviation cable to the middle input port on AC300 Figure 4 1 2 3 4 4 1 2 2 3 3 1 Easy ste...

Page 25: ...50VDC 12A 2 Note This PV module doesn t work with solar panels that have built in microinverters and open circuit voltage over 550V Rigid panel charging b a c d a b c d a DC Output Cable to AC300 c DC2 poles to PV2 poles b DC1 poles to PV1 poles d DC Output Cable to D300S 8 2 2 Charging Method 4 Car Charging Press the power button and connect it to the cigarette lighter port through the car chargi...

Page 26: ...tion Port 1 CP1 Aviation Port 1 CP2 EV Charging Station Wind Turbine Generator Solar panels T500 adapter Car Lead acid Battery By using BLUETTI Wind Turbines an ultra connect highly efficient wind charger lets you harness the wind to rapidly recharge the AC300 B300 Now you can also get dash charging via the EV charging stations all over the US soil Charging Method 6 Supports charging the AC300 B30...

Page 27: ...age battery DC Input Source 1 Select Others on the touchscreen Method 6 24V Car Charger Storage battery DC Input Source 1 Select Others on the touchscreen DC Input2 Method 7 Solar panels DC Input Source 2 Select PV on the touchscreen Method 8 T500 charging adapter DC Input Source 2 Select Others on the touchscreen Method 9 12V Car Charger Storage battery DC Input Source 2 Select Others on the touc...

Page 28: ...to factors such as ambient temperature discharge rate remaining battery capacity altitude and other factors 9 1 The Output Port 9 1 1 AC Output Port AC300 is equipped with 7 AC US JP version 6 AC AU EU UK outputs with a continuous 3000W Max power of output in total and the ability to support surges up to 6000W Please make sure the combined power requirements of your appliances does not exceed the ...

Page 29: ...n 6 220 240V 20A Only the NEMA TT 30 can generate 3000W 30A power of output the standard AC output port can produce 2000 2400W 20A power of output 9 1 2 DC Output Port 1 1 RV port 2 1 24V 10A Cigarette Lighter Port 3 1 USB C PD 100W 4 1 Power button 5 2 USB A fast charging 6 2 USB A 1 2 3 4 5 6 ...

Page 30: ...s Home Equipment Space Heater 1500W 3 2 Hrs Air Conditioner 8000Btu 2 Hrs Smart Phone 18Wh 115 Times Laptop 45Wh 71 Times Desktop 300W 14 5 Hrs CPAP 40W 77 Hrs Tools Bench Grinder 1400W 3 5 Hrs Welding Machine 1800W 2 8 Hrs Circular Saw 1400W 2300W 2 1 3 5 Hrs Transportation Electric Vehicle 16A 1800W 13 5 16 Miles E Bike 500W 9 2 Times The estimation operating time is only for reference ...

Page 31: ... power to a load when the input power source or mains power fails A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near instantaneous protection from input power interruptions by supplying energy stored in batteries supercapacitors or flywheels 10 1 1 FYI For Your Information Max capacity retention indicates the limit of capacity of the unit th...

Page 32: ...to the AC input port Step3 Connect the load to AC300 via AC output port Note The output power in Plug in UPS Mode is subject to the specification of the current and voltage from home circuit a Standard UPS Mode b Time Control UPS Mode c PV Priority UPS Mode d Customized UPS Mode Eg Current 15A wire X Voltage 120V 1800W in US Eg Current 30A wire X Voltage 120V 3000W in US 10 1 3 Turn On UPS Functio...

Page 33: ... its battery Charge Time Set the time of when the AC300 B300 is to be recharged by grid to avoid the higher electricity rates Discharge Time Set the time to switch to batteries to power loads connected to the Sub Panel Optional Purchase Parameter Setting Battery SOC Low When the remaining capacity of AC300 B300 is under the preset High Low battery capacity AC300 B300 will stop powering connected l...

Page 34: ...or power savings Note In PV Priority Mode AC300 can only be recharged via grid to 30 capacity and also discharge to 30 of the capacity you can tweak it to 100 for full grid charging manually on touchscreen or App as the Reserved capacity for PV charging And rest of the capacity will be fully charged from either solar power or 2 adaptors ...

Page 35: ... will not charge batteries from grid Apart from Time Control UPS the main switch of grid charging and time mode settings are involved The setting of Time Setting and SOC Setting will take effect on both PV Priority Mode and Time Control Mode 11 SPLIT PHASE FUNCTION 1 NEMA L14 30 receptacle 30A 2 NEMA TT 30 receptacle 30A 4 Standard AC receptacle 20A ...

Page 36: ...of AC input plug 30A Note 1 Please disconnect the AC charging cable for both AC300 units while binding into Fusion Box Pro 2 Certificated Technician is required to build the split phase system to power the Sub Panel Warning If you insist to charge the AC300 which has been connected into Fusion Box Pro already please make sure the L1 L2 N wire is set at the right phase sequence or the AC300 will be...

Page 37: ...ble in Split Phase System please use Fusion AC Input Cable Optional Purchase to charge the two set of the AC300 B300 in Split Phase System Wrong Connection will damage the power station and your warranty will be invalid BLUETTI will not take responsible for the damage caused by personal negligence or wrong operation PE G PE W N L1 X L1 N PE G PE W N L1 X L1 N ...

Page 38: ...nction Note If one of the AC300 is out of power the Split Phase Bonding function will deactivate automatically Step 1 Plug the output cables from each of the two AC300 to the Split Fusion Box Pro Step 2 Plug the communication cables from each of the two AC300 to the Split Fusion Box Pro Step 3 Set the Machine Type to Split Phase on AC300 either Step 4 Select Master or Slave on the operating AC300 ...

Page 39: ...E UN38 3 msds UL SAA and ROHS Capacity 3072 12288Wh 60 240Ah Battery Type LiFePO4 Standard Battery Voltage 51 2VDC Battery Cell Voltage Range 44 8 57 6VDC Short circuit Protection Included Over temperature Protection Included MPPT Built in Over temperature Protection Discharge Over temperature 65 Discharge Over temperature Recovery 55 Charge Over temperature 55 Charge Over temperature Recovery 45 ...

Page 40: ...al USB C Type C 1 5 15VDC 3A 20VDC 5A 100W Wireless Charging Pad 2 5 7 5 10 15W 2 RV Port 1 12VDC 30A 418W load 2S AC Input Input Voltage 85 110VAC JP 102 132VAC US 207 253VAC EU UK AU Input Frequency 47Hz 63Hz Max Input Current 30A Configurable Input Current Preset at 15A can be changed on screen AC Charging Voltage Range 90 264VAC AC Charging Frequency Range 47Hz 63Hz Power of Charging 3000W Max...

Page 41: ...h the dealer if the error still exists after rebooting the unit 007 Fan Warning Hardware Clean or replace the fan to ensure proper ventilation Please contact with the dealer if the error still exists after rebooting the unit Please turn off the unit and charge it to 50 70 capacity every time before storing it To preserve the battery health please discharge and fully charge the unit at least once e...

Page 42: ...ct with the dealer if the error still exists after rebooting the unit 016 DC Input Voltage Low Please contact with the dealer if the error still exists after rebooting the unit 017 DC Input Over Current Please contact with the dealer if the error still exists after rebooting the unit 018 Inverter Output Over Current The output power of load exceeds Please contact with the dealer if the error still...

Page 43: ... exists after rebooting the unit 028 Load Relay Open Circuit Please contact with the dealer if the error still exists after rebooting the unit 029 INV Soft Start Failure Please contact with the dealer if the error still exists after rebooting the unit 049 PV1 Over Current Please contact with the dealer if the error still exists after rebooting the unit 050 PV2 Over Current Please contact with the ...

Page 44: ... alarm history or restart the unit 063 Multi Synchronization Error Please check whether the communication cable is connected correctly Clear the alarm history or restart the unit 064 Multi Brak Phase Error Please check if the input of the AC voltage meets the specifications of the unit Clear the alarm history or restart the unit 065 PV Paralleling Error Please check whether the PV parallel enable ...

Page 45: ...r restart the unit 091 DC Output soft start Failure Please contact with the dealer if the error still exists after rebooting the unit 092 DC 12V 30A Output Short Circuit Please disconnect the appliances on DC output ports 093 DC 24V 10A Output Short Circuit Please disconnect the appliances on DC output ports 094 USB TYPE C PD Port Locked Please disconnect the load to make sure the output power of ...

Page 46: ...3 BMS communication cable error Please check whether the battery power cable is reliably connected Please check whether the lock switch on the power cable has been turnd on Please contact with the dealer if the error still exists after rebooting the unit 107 NTC Faulty Please leave the unit at the recommended temperature few hours to recover Please contact with the dealer if the error still exists...

Page 47: ...0S to drop down the voltage of the panels to achieve solar charging How do I know whether my appliance can work well with the power station Calculate how much the continuous loads are for your appliances are in total As long as they do not exceed the rated output power of the power station it should work How can I connect the product to my main panel To install the grid tie power system an electri...

Page 48: ...uld void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy if not installed and...

Page 49: ...Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 0 65ft between the radiator and your body ...

Page 50: ... Lindwurmstr 114 80337 München Germany Mail logi bluetti de Company POWEROAK ENERGY UK CO LTD Address Suite 108 Chase Business Center 39 41 Chase Side London United Kingdom N14 5BP Mail poweroak eu bluetti com P N 17 0303 0400 01A1 ...

Reviews: