33
Just Power On
CONNECTION 2 (Power Mode)
In Split Phase Power System, it is recommended that you choose the
Fusion AC
Input Cable
. The AC input ports of the two set of AC300+B300 should be connected
to be as the phase sequence: L1,N,PE and L2,N,PE. Make sure that the phase
sequence of the two machines is correct.
Wrong Connection will damage the power station and your warranty will be
invalid, BLUETTI will not take responsibility for the damage caused by personal
negligence or wrong operation.
The Fusion AC Input Cable(Optional Purchase) is designed to power the Split Phase
System. One end of the cable is going to be connected to NEMA L14-30 socket, and
connect the aviation plugs to the AC input ports of the two set of AC300+B300.
The current of AC input plug: ≥ 30A.
Note:
(1) Please disconnect the AC charging cable for both AC300 units while
binding into Fusion Box Pro.
(2) Certificated Technician is required to build the split phase system to
power the Sub Panel.
Warning: If you insist to charge the AC300 which has been connected
into Fusion Box Pro already, please make sure the L1/L2/N wire is set at
the right phase sequence or the AC300 will be damaged.
L: Live wire N: Neutral wire
CONNECTION 1 (Standard Mode)
“Single Phase” is set as the default machine type if you are operating a single
AC300+B300 system. It`s the only and correct setting if a single AC300+B300
is being used. "Machine Type" is only used to set for Split Phase, “Split Phase” is
only used for connecting both *2 AC300+B300 (exclusive for AC300 100-120V
Version) bonded 2 pairs of AC300+B300 to one power supply system to double
the output power, voltage, so as to capacity. Please refer to Split Phase Setting
for detailed information.