TA200
www.baumer.com
25
6 Technical data
Technical data - electrical ratings
Voltage supply
115/230 VAC ±10 % (50/60 Hz)
24/48 VAC ±10 % (50/60 Hz)
24 VDC ±10 %
Power consumption
7 VA, 5 W
Sensor supply
12...26 VDC / max. 100 mA
Display
LED, 7-segment display
Number of digits
6-digits
Digit height
14 mm
Unit displayed
1/s, 1/min, 1/h programmable
Programmable
Measuring units 1/h, 1/min, 1/s
parameters
Scaling factor
Sensor logic
Pulse frequency
Function
Tachometer
Measuring principle
Period duration measurement
Signal inputs
Comparator inputs
Input logic
NPN / PNP
Counting frequency
25 Hz, 40 kHz programmable
Scaling factor
0.0001...9999.99
Data memory
>10 years in EEPROM
Standard DIN EN 61010-1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-3
Interference immunity
DIN EN 61000-6-2
Approvals
UL approval / E63076
Technical data - mechanical design
Ambient temperature
0...+50 °C
Storing temperature
-20...+70 °C
Relative humidity
80 % non-condensing
E-connection
Plug-in screw terminals
Core cross-section
1.5 mm²
Protection DIN EN 60529
IP 65 (face with seal)
Operation / keypad
Membrane with softkeys
Housing type
Built-in housing
Dimensions W x H x L
96 x 48 x 124 mm
Cutout dimensions
92 x 44 mm (-0.6)
Installation depth
124 mm
Mounting
Front panel installation by clip frame
Weight approx.
350 g (AC), 250 g (DC)
Material
Housing: Makrolon 6485 (PC)