WIDTH: Width measurement
To perform width measurement, select FUNCTION
"WIDTH" in the menu. In WIDTH the desired output is
selected in the MEAS TYPE menu.
OBJECT WIDTH
= Distance between the first rising
flank from the left and the first
rising flank from the right.
OBJECT CENTER
= Center between the first
rising flank from the left and the
first rising flank from the right in
relation to the measuring axis of
the sensor.
OBJECT WIDTH
OBJECT CENTER
OBJECT HEIGHT
Minimum height of the object to be measured.
OBJECT
Selection of light or dark objects to optimize the
measurement results.
PRECISION
For more reliable measurement results, the output values
can be filtered with High and Very High.
FLEX MOUNT
If the sensor is mounted at an angle, FLEX MOUNT must
be activated and the reference surface must be taught in.
1. Activate FLEX MOUNT
2. Align and confirm sensor or reference surface
3. When all conditions are met (see table on right),
confirm by pressing Set for 2 seconds
4. Enter thickness of the auxiliary plate (if present)
Distance between sensor
and reference surface
Installation angle too
large
Reference surface too
uneven
Reference surface too
small (<50 mm)
3b
Min. object height
Object
Reference